A multi-laboratory benchmark study of isothermal titration calorimetry (ITC) using Ca2+ and Mg2+ binding to EDTA

Archive ouverte

Velazquez-Campoy, Adrian | Claro, Bárbara | Abian, Olga | Höring, Jonas | Bourlon, Louis | Claveria-Gimeno, Rafael | Ennifar, Eric | England, Patrick | Chaires, Jonathan, Brad | Wu, Di | Piszczek, Grzegorz | Brautigam, Chad | Tso, Shih-Chia | Zhao, Huaying | Schuck, Peter | Keller, Sandro | Bastos, Margarida

Edité par CCSD ; Springer Verlag (Germany) -

International audience. A small-scale ITC benchmarking study was performed involving 9 biophysics laboratories/facilities, to evaluate interlaboratory and intra-laboratory basal levels of uncertainty. Our prime goal was to assess a number of important factors that can influence both the data gathered by this technique and the thermodynamic parameter values derived therefrom. In its first part, the study involved 5 laboratories and 13 different instruments, working with centrally prepared samples and the same experimental protocol. The second part involved 4 additional laboratories and 6 more instruments, where the users prepared their own samples according to provided instructions and did the experiments following the same protocol as in the first part. The study design comprised: (1) selecting a minimal set of laboratories; (2) providing very stable samples; (3) providing samples not requiring preparation or manipulation; and (4) providing a well-defined and detailed experimental protocol. Thus, we were able to assess: (i) the variability due to instrument and data analysis performed by each user on centrally prepared samples; (ii) the comparability of data retrieved when using 4 different software packages to analyze the same data, besides the data analysis carried out by the different users on their own experimental results; and (iii) the variability due to local sample preparation (second part of the study). Individual values, as well as averages and standard deviations for the binding parameters for EDTA-cation interaction, were used as metrics for comparing the equilibrium association constant (logK), enthalpy of interaction (ΔH), and the so-called "stoichiometry" (n), a concentration-correction factor.

Consulter en ligne

Suggestions

Du même auteur

Reproducibility and accuracy of microscale thermophoresis in the NanoTemper Monolith: a multi laboratory benchmark study

Archive ouverte | López-Méndez, Blanca | CCSD

International audience. Microscale thermophoresis (MST), and the closely related Temperature Related Intensity Change (TRIC), are synonyms for a recently developed measurement technique in the field of biophysics to...

A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation

Archive ouverte | Zhao, Huaying | CCSD

International audience. Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, report...

MeCP2-E1 isoform is a dynamically expressed, weakly DNA-bound protein with different protein and DNA interactions compared to MeCP2-E2

Archive ouverte | Martínez de Paz, Alexia | CCSD

International audience. Background: MeCP2-a chromatin-binding protein associated with Rett syndrome-has two main isoforms, MeCP2-E1 and MeCP2-E2, differing in a few N-terminal amino acid residues. Previous studies h...

Chargement des enrichissements...