EURADOS intercomparison exercise on MC modelling for the in-vivo monitoring of AM-241 in skull phantoms (Part II and III)

Archive ouverte

Vrba, T. | Broggio, D. | Caldeira, M. | Capello, K. | Fantínová, K. | Franck, D. | Goméz-Ros, J.M. | Hunt, J. | Kinase, S. | Leone, D. | Lombardo, P.A. | Manohari, M. | Marzocchi, O. | Moraleda, M. | Nogueira, P. | Ośko, J. | Arron, S. | Suhl, S. | Takahashi, M. | Teles, P. | Tremblay, M. | Tymińska, K. | Lopez, M.A. | Tanner, R.

Edité par CCSD ; Elsevier -

International audience. An intercomparison on in-vivo monitoring for determination of Am-241 in three skull phantoms was launched by EURADOS in 2011. The project focused on measurement and estimation of the activity of Am-241 in the human skull. Three human skull phantoms of different complexity were used. A Monte Carlo (MC) intercomparison exercise with the voxel representations of the physical phantom was launched additionally in September of 2012. The main goals of the action were (1) to investigate the different methodologies for developing MC calibrations that might arise from a complex radiological assessment and (2) to compare individual approaches of the participating laboratories in order to determine international guidance for best practice. The MC exercise consisted of three tasks with increasing difficulty, in order to test the extent of skills needed by the participating laboratory. The first task was to simulate a given detector and a well-defined semi-skull phantom. The second and third tasks presented in this paper-introduced more complex simulations with individual geometry and real detector modelling. The paper provides an overview of the participant's results, analyses of the observed issues concerning tasks two and three, and a general evaluation of the whole project. © 2015 Elsevier Ltd.

Consulter en ligne

Suggestions

Du même auteur

EURADOS intercomparison exercise on MC modeling for the in-vivo monitoring of Am-241 in skull phantoms (Part I)

Archive ouverte | Vrba, T. | CCSD

International audience. An intercomparison on in-vivo monitoring for determination of 241Am in three skull phantoms was launched by EURADOS in 2011. The project focused on the measurement and estimation of 241Am act...

Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison

Archive ouverte | Broggio, D. | CCSD

International audience. In order to assess the reliability of Monte Carlo (MC)-based numerical calibration of in vivo counting systems the EURADOS network supported a comparison of MC simulation of well-defined expe...

EURADOS 241Am skull measurement intercomparison

Archive ouverte | Franck, D. | CCSD

International audience. In 2011 a measurement intercomparison was launched by EURADOS WG7, with the objective of providing the participants with the tools to calibrate their detection systems for detection of 241Am ...

Chargement des enrichissements...