Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison

Archive ouverte

Broggio, D. | Bento, J. | Caldeira, M. | Cardenas-Mendez, E. | Farah, J. | Fonseca, T. | Konvalinka, C. | Liu, L. | Perez, B. | Capello, K. | Cowan, P. | Cruzate, J.-A. | Freire, L. | Gómez-Ros, J.-M. | Gossio, S. | Heide, B. | Huikari, J. | Hunt, J. | Kinase, S. | Kramer, G.H. | Kurihara, O. | Kyrieleis, A. | Lebacq, A.-L. | Leone, D. | Li, C. | Li, J. | Mihailescu, L.-C. | Moraleda, M. | Navarro, J.-F. | Oliveira, C. | Puerta, N. | Reichelt, U. | Simões, C. | Sommer, D. | Takahashi, M. | Teles, P. | Vanhavere, F. | Vrba, T. | Franck, D. | Gualdrini, G. | Lopez, M.-A.

Edité par CCSD ; Elsevier -

International audience. In order to assess the reliability of Monte Carlo (MC)-based numerical calibration of in vivo counting systems the EURADOS network supported a comparison of MC simulation of well-defined experiments. This action also provided training for the use of voxel phantoms. In vivo measurements of enriched uranium in a thoracic phantom have been carried out and the needed information to simulate these measurements was distributed to 17 participants. About half of the participants managed to simulate the measured counting efficiency without support from the organisers. Following additional support all participants managed to simulate the counting efficiencies within a typical agreement of ±5% with experiment. © 2012 Elsevier Ltd. All rights reserved.

Consulter en ligne

Suggestions

Du même auteur

Monte Carlo modelling of Germanium detectors for the measurement of low energy photons in internal dosimetry: Results of an international comparison

Archive ouverte | Goméz-Ros, J.M. | CCSD

International audience. This communication summarizes the results concerning the Monte Carlo (MC) modelling of Germanium detectors for the measurement of low energy photons arising from the "International comparison...

EURADOS intercomparison exercise on MC modelling for the in-vivo monitoring of AM-241 in skull phantoms (Part II and III)

Archive ouverte | Vrba, T. | CCSD

International audience. An intercomparison on in-vivo monitoring for determination of Am-241 in three skull phantoms was launched by EURADOS in 2011. The project focused on measurement and estimation of the activity...

EURADOS intercomparison exercise on MC modeling for the in-vivo monitoring of Am-241 in skull phantoms (Part I)

Archive ouverte | Vrba, T. | CCSD

International audience. An intercomparison on in-vivo monitoring for determination of 241Am in three skull phantoms was launched by EURADOS in 2011. The project focused on the measurement and estimation of 241Am act...

Chargement des enrichissements...