SESAME A TOOL FOR NUMERICAL DOSIMETRIC RECONSTRUCTION OF PATIENTS OVEREXPOSURES IN INTERVENTIONAL RADIOLOGY

Archive ouverte

Huet, C. | Entine, F. | Bassinet, C. | Dondey, M. | Dreuil, S. | Georges, J.-L. | Etard, C. | Clairand, I.

Edité par CCSD ; Oxford University Press (OUP) -

International audience. Radiation overexposure accidents are rare but can have severe health consequences. Evaluating the dose received by the patient is a crucial step in the medical management. For that purpose, for more than 15 years, IRSN has been developing an in-house tool named SESAME for the numerical reconstruction of radiological accidents due to external sources. Recently, two new functionalities were implemented in SESAME to allow accurate reconstructions of interventional radiology (IR) overexposures. The experimental validation of SESAME for the reconstruction of overexposures in IR is presented. First, an anthropomorphic dummy equipped with dosemeters was irradiated following conditions similar to a fluoroscopically guided interventional procedure. Then the procedure was simulated using SESAME. Finally measured doses were compared to calculated doses. Even with a limited amount of data available, SESAME can provide valuable dose information for the medical team in charge of the patient, such as skin dose mapping and dose distribution in depth. © The Author(s) 2019. Published by Oxford University Press. All rights reserved. For Permissions, please email journals.permissions@oup.com.

Consulter en ligne

Suggestions

Du même auteur

Characterization of MOSFET detectors for in vivo dosimetry in interventional radiology and for dose reconstruction in case of overexposure

Archive ouverte | Bassinet, C. | CCSD

International audience. As MOSFET (Metal Oxide Semiconductor Field Effect Transistor) detectors allow dose measurements in real time, the interest in these dosimeters is growing. The aim of this study was to investi...

Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones

Archive ouverte | Bassinet, C. | CCSD

Erratum: Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones (Medical Physics (2013) 40 (071725)) ...

Radiation doses to patients in interventional coronary procedures-estimation of updated national reference levels by dose audit

Archive ouverte | Georges, J.-L. | CCSD

International audience. The objective of this study was to estimate the French national updated reference levels (RLs) for coronary angiography (CA) and percutaneous coronary intervention (PCI) by a dose audit from ...

Chargement des enrichissements...