First clinical evaluation of a new single-use flexible cystoscope dedicated to double-J stent removal (Isiris™): a European prospective multicenter study

Archive ouverte

Doizi, Steeve | Kamphuis, Guido | Giusti, Guido | Palmero, Jl | Patterson, Jm | Proietti, Silvia | Straub, Michael | de La Rosette, Jean | Traxer, Olivier

Edité par CCSD ; Springer Verlag -

International audience. PurposeWe evaluated a new single-use digital flexible cystoscope with an integrated grasper designed for double-J stent removal, Isiris™, addressing success rate, image quality, deflection, maneuverability and grasper functionality.MethodsIn September 2015, a prospective cohort study was conducted in six tertiary European reference centers. All consecutive patients included underwent double-J stent removal and were 18 years or older. Success rate was defined by complete stent removal. Image quality, deflection, maneuverability and grasper functionality were rated with a Likert scale.ResultsA total of 83 procedures were performed. 82% of procedures were performed in the endoscopy room, while the others were in the operating room since a consecutive endourological intervention was planned. The median duration of stent implantation was 28 days [14; 60]. In five patients, stent removal was not possible. Four patients had an incrusted double-J stent, and in one patient, the stent migrated into the ureter. After unsuccessful attempts of stent removal with conventional flexible cystoscope and grasper, the five patients had to be scheduled for an ureterorenoscopy procedure to remove the stent. In the other 78 patients, all double-J stents were removed successfully. Image quality, deflection, maneuverability and grasper functionality were rated as “very good” in 72.3, 78.3, 72.3 and 73.5%, respectively.ConclusionThis multicenter clinical evaluation of Isiris™ displayed good image quality, active deflection, maneuverability and grasper functionality. Further evaluation of stent removal outcomes, cost analysis and microbiology will help to delineate the possible place of Isiris™ in the current practice.

Suggestions

Du même auteur

Consultation on UTUC, Stockholm 2018 aspects of diagnosis of upper tract urothelial carcinoma

Archive ouverte | Fojecki, Grzegorz | CCSD

International audience. PURPOSE: To summarize knowledge on upper urinary tract carcinoma (UTUC) regarding diagnostic procedures, risk factors and prognostic markers.METHODS: A scoping review approach was applied to ...

Consultation on UTUC, Stockholm 2018 aspects of risk stratification: long-term results and follow-up

Archive ouverte | Hasan, Mudhar, N | CCSD

International audience. PURPOSE : To summarize current knowledge on upper urinary tract carcinoma (UTUC) regarding risk stratification, long-term results, and follow-up.METHODS : A scoping review approach was applie...

Comparison of Holmium:YAG and Thulium Fiber Lasers on the Risk of Laser Fiber Fracture

Archive ouverte | Uzan, Audrey | CCSD

International audience. Objectives: To compare the risk of laser fiber fracture between Ho:YAG laser and Thulium Fiber Laser (TFL) with different laser fiber diameters, laser settings, and fiber bending radii.Method...

Chargement des enrichissements...