0346 : Procedural safety and long-term follow-up after pacemaker implantation in nonagenarians

Archive ouverte

Loirat, Aurelie | Feneon, Damien | Behaghel, Albin | Behar, Nathalie | Le Helloco, Alain | Mabo, Philippe | Daubert, Jean-Claude | Leclercq, Christophe | Martins, Raphael

Edité par CCSD -

International audience. Introduction The rate of pacemaker(PM) implantations is continuously growing. A large number of nonagenarian patients will be implanted in the future. We aimed at analyzing the outcome after PM implantation in the elderly. Methods Patients aged ≥90 yo referred for PM implantation from 2004 to 2014 were retrospectively included. The primary clinical endpoint was total mortality. Results 113 patients were included (92.6±2.1yo). Five patients (3.5%) had short-term device-related complications (3 pocket hematoma, 1 lead displacement, 1 hemothorax). During the follow-up, 48 patients (42.5%) died. Survival rates were 77.4% (95%CI:67.4-84.7%), 68.7% (95%CI:57.4-77.6%) and 36.4% (95%CI:23.3-49.7%) after 1, 2 and 5 years, respectively. Atrial fibrillation (OR 3.5,95%CI:1.6-7.2) and a cardiomyopathy (OR 2.3,95%CI:1.2-4.4) at the time of implantation were independent predictors of mortality. Conclusion PM implantation in nonagenarians is safe, with a low risk of procedural complications. Figure: Survival for nonagenarians after PM implantation

Consulter en ligne

Suggestions

Du même auteur

0344 : Pacemaker replacement in nonagenarians: procedural safety and long-term follow-up

Archive ouverte | Loirat, Aurelie | CCSD

International audience. Background The rate of pacemaker (PM) implantations is continuously growing. A large number of elderly patients is expected to be implanted in the future. We aimed at analyzing the short and ...

Electrocardiographic correlates of mechanical dyssynchrony in recipients of cardiac resynchronization therapy devices

Archive ouverte | Mabo, Philippe | CCSD

International audience. Background The relationship between electrical and mechanical indices of cardiac dyssynchronization in systolic heart failure (HF) remains poorly understood. Objectives We examined retrospect...

Procedural safety and long-term follow-up after pacemaker implantation in nonagenarians

Archive ouverte | Dang, Duc | CCSD

International audience. Background - The rate of pacemaker (PM) implantations is constantly growing. Since life expectancy of the population is projected to increase, a large number of nonagenarian patients will nee...

Chargement des enrichissements...