Procedural safety and long-term follow-up after pacemaker implantation in nonagenarians

Archive ouverte

Dang, Duc | Galand, Vincent | Loirat, Aurelie | Auffret, Vincent | Behar, Nathalie | Mabo, Philippe | Daubert, Jean-Claude | Leclercq, Christophe | Martins, Raphael P.

Edité par CCSD ; Wiley -

International audience. Background - The rate of pacemaker (PM) implantations is constantly growing. Since life expectancy of the population is projected to increase, a large number of nonagenarian patients will need PM implantation. We aimed at analyzing short- and long-term outcomes after PM implantation in nonagenarians. Methods - Patients aged ≥90 years referred for PM implantation from 2004 to 2017 were included. The primary clinical endpoint was total mortality. Secondary endpoints included procedure-related and in-hospital complications. Results - A total of 172 patients were included (92.6 ± 2.1 years, from 90.0 to 101.4 years). Procedure duration was 50.0 ± 19.7 minutes. Most of the patients had VVI devices implanted (143 pts, 83.1%) and mean hospital stay was 3.5 ± 1.5 days. Nine patients (5.2%) had short-term device-related complications and 29 patients (16.8%) had post-procedural complications, non-related to the implantation, including four leading to patients' death. During a follow-up of 22.5 months (interquartile range: 7.3-38.0), 94 patients (54.7%) died. Survival rates were 82.9% (95% confidence interval [CI]: 76.0-88.0), 73.7% (95% CI: 65.7-80.1) and 37.5% (95% CI: 27.5-47.5) after 1, 2, and 5 years, respectively. The Charlson comorbidity index was a predictive factor of procedural complications (odds ratio = 1.33; 95% CI: 1.05-1.69, P = 0.02) while having a complication (hazard ratio [HR] = 4.04; 95% CI: 1.79-9.11, P = 0.001) and atrial fibrillation (HR = 1.63; 95% CI: [1.02-2.63], P = 0.043) were predictors of post-implantation death. Conclusion - PM implantation in nonagenarians is safe, with a low risk of procedural complications, but many comorbidities-related complications can occur. Caution should be taken in this old and frail population since complications significantly impact patients' survival.

Suggestions

Du même auteur

The second generation cryoballoon has improved durable isolation of left but not right pulmonary veins new insights from amulticentre study

Archive ouverte | Martins, Raphael P. | CCSD

International audience. Aims Pulmonary vein isolation (PVI) using second-generation cryoballoon (CB2) is associated with improved outcomes compared with first generation (CB1). We aimed at investigating the characte...

Radiofrequency ablation of right ventricular tachycardia in patients with no femoral access safety and efficacy of a superior approach

Archive ouverte | Martins, Raphael P. | CCSD

International audience

0346 : Procedural safety and long-term follow-up after pacemaker implantation in nonagenarians

Archive ouverte | Loirat, Aurelie | CCSD

International audience. Introduction The rate of pacemaker(PM) implantations is continuously growing. A large number of nonagenarian patients will be implanted in the future. We aimed at analyzing the outcome after ...

Chargement des enrichissements...