Twenty-two years later: consistent dose estimation of an accidental overexposure by retrospective biological dosimetry

Archive ouverte

Martinez Guerrero, Juan | Gregoire, Eric | Fernandez, Pascale | Dugue, Delphine | Jikia, D | Gruel, Gaëtan

Edité par CCSD ; Oxford University Press (OUP) -

International audience. The goal of this study was to retrospectively estimate the exposure dose of a victim from the Lilo radiological accident in Georgia after 22 y and compare it with the original cytogenetics-based analysis performed in our laboratory. Similar types of studies have been published, notably involving victims of the Chernobyl, Goiânia and Tammiku accidents. Nevertheless, their estimations were done after shorter periods of time post-exposure, and in some cases, the exposure might not have been exclusively of an external nature. In this study, Fluorescence In Situ Hybridization (FISH) was used to score chromosomal translocations in lymphocytes from a recent blood sample of the victim and the dose assessment was performed using our laboratory's FISH calibration curve. The resulting whole-body exposure dose of 0.35 Gy [0.12, 0.72] was similar to the one obtained when reanalysing the original scoring data from 1997 (0.38 Gy [0.13-0.75]), suggesting that our current calibration curve could be used for relative dose estimations long time after external exposure.

Suggestions

Du même auteur

Twenty-two years later: Consistent dose estimation of an accidental overexposure by retrospective biological dosimetry

Archive ouverte | Martinez Guerrero, Juan | CCSD

International audience. As the chromosomal translocation rate increases with age in the non-exposed population, the translocation-based dose estimation of an external radiation exposure victim needs to take into con...

Differential Recruitment of DNA Repair Proteins KU70/80 and RAD51 upon Microbeam Irradiation with α-Particles

Archive ouverte | Bobyk, Laure | CCSD

International audience. In addition to representing a significant part of the natural background radiation exposure, α-particles are thought to be a powerful tool for targeted radiotherapy treatments. Understanding ...

RENEB/EURADOS field exercise 2019: robust dose estimation under outdoor conditions based on the dicentric chromosome assay

Archive ouverte | Endesfelder, David | CCSD

International audience. Purpose: Biological and/or physical assays for retrospective dosimetry are valuable tools torecover the exposure situation and to aid medical decision making. To further validate andimprove s...

Chargement des enrichissements...