High-intensity focused ultrasound ablation for the treatment of colorectal liver metastases during an open procedure: study on the pig.

Archive ouverte

Parmentier, Hubert | Melodelima, David | N'Djin, William Apoutou | Chesnais, Sabrina | Chapelon, Jean Yves | Rivoire, Michel

Edité par CCSD ; Lippincott, Williams & Wilkins -

International audience. OBJECTIVE: To demonstrate in a porcine model that high-intensity focused ultrasound (HIFU) with toroid-shaped emitters may have a role in treating unresectable colorectal liver metastases. SUMMARY BACKGROUND DATA: Surgical resection is the only curative option for colorectal hepatic metastases. Only 20% of patients are suitable for surgery. Many ablative techniques have been assessed but several limitations have been documented: traumatic puncture of the parenchyma, limited size of lesions, and inability to monitor the treatment in real time. METHODS: A HIFU device with 256 toroid-shaped emitters and integrated ultrasound imaging probe was used. Single lesions, induced in 40 seconds, and juxtaposition of 6 single lesions were created under ultrasound guidance on 13 pigs. The lesions were studied on sonograms, macroscopically and microscopically up to 30 days after the treatment. RESULTS: Ninety percent of the HIFU lesions were immediately hypoechoic on ultrasound imaging. The average coagulated volume obtained from a 40 seconds total exposure in the liver was 7.0 +/- 2.5 cm (1.5-20.0), average diameter: 19.5 +/- 3.8 mm (10.0-29.0). Using the real-time visualization of the treated region, single lesions were easily juxtaposed to produce larger lesions up to 6 cm in diameter without any major complication. CONCLUSIONS: This toroid HIFU device allows short treatment times, noninvasiveness regarding the liver and real time ultrasound guidance. It seems to be simpler and more reliable to use than current ablative methods. Additionally, lesions through large vessels (up to 5 mm) being feasible, treatment of some juxta-vascular metastases should be possible.

Suggestions

Du même auteur

Utility of a tumor-mimic model for the evaluation of the accuracy of HIFU treatments. results of in vitro experiments in the liver.

Archive ouverte | N'Djin, William Apoutou | CCSD

International audience. Presented in this article is a tumor-mimic model that allows the evaluation, before clinical trials, of the targeting accuracy of a high intensity focused ultrasound (HIFU) device for the tre...

A Tumor-mimic Model for Evaluating the Accuracy of HIFU Preclinical Studies: An In Vivo Study.

Archive ouverte | N'Djin, William Apoutou | CCSD

International audience. To date, the efficacy of ablative technologies such as HIFU for the treatment of liver tumors in humans has been studied in animal models without tumors or in small animals like rats and rabb...

Toric HIFU Transducer for Large Thermal Ablation.

Archive ouverte | Melodelima, David | CCSD

International audience. A new geometry of High Intensity Focused Ultrasound (HIFU) transducer is described to enlarge the coagulated volume and decrease treatments time. Eight transducer elements and their quarter-w...

Chargement des enrichissements...