Utility of a tumor-mimic model for the evaluation of the accuracy of HIFU treatments. results of in vitro experiments in the liver.

Archive ouverte

N'Djin, William Apoutou | Melodelima, David | Parmentier, Hubert | Chesnais, Sabrina | Rivoire, Michel | Chapelon, Jean Yves

Edité par CCSD ; Elsevier -

International audience. Presented in this article is a tumor-mimic model that allows the evaluation, before clinical trials, of the targeting accuracy of a high intensity focused ultrasound (HIFU) device for the treatment of the liver. The tumor-mimic models are made by injecting a warm solution that polymerizes in hepatic tissue and forms a 1 cm discrete lesion that is detectable by ultrasound imaging and gross pathology. First, the acoustical characteristics of the tumor-mimics model were measured in order to determine if this model could be used as a target for the evaluation of the accuracy of HIFU treatments without modifying HIFU lesions in terms of size, shape and homogeneity. On average (n = 10), the attenuation was 0.39 +/- 0.05 dB.cm(-1) at 1 MHz, the ultrasound propagation velocity was 1523 +/- 1 m.s(-1) and the acoustic impedance was 1.84 +/- 0.00 MRayls. Next, the tumor-mimic models were used in vitro in order to verify, at a preclinical stage, that lesions created by HIFU devices guided by ultrasound imaging are properly positioned in tissues. The HIFU device used in this study is a 256-element phased-array toroid transducer working at a frequency of 3 MHz with an integrated ultrasound imaging probe working at a frequency of 7.5 MHz. An initial series of in vitro experiments has shown that there is no significant difference in the dimensions of the HIFU lesions created in the liver with or without tumor-mimic models (p = 0.3049 and p = 0.8796 for the diameter and depth, respectively). A second in vitro study showed that HIFU treatments performed on five tumor-mimics with safety margins of at least 1 mm were properly positioned. The margins obtained were on average 9.3 +/- 2.7 mm (min. 3.0 - max. 20.0 mm). This article presents in vitro evidence that these tumor-mimics are identifiable by ultrasound imaging, they do not modify the geometry of HIFU lesions and, thus, they constitute a viable model of tumor-mimics indicated for HIFU therapy.

Consulter en ligne

Suggestions

Du même auteur

High-intensity focused ultrasound ablation for the treatment of colorectal liver metastases during an open procedure: study on the pig.

Archive ouverte | Parmentier, Hubert | CCSD

International audience. OBJECTIVE: To demonstrate in a porcine model that high-intensity focused ultrasound (HIFU) with toroid-shaped emitters may have a role in treating unresectable colorectal liver metastases. SU...

A Tumor-mimic Model for Evaluating the Accuracy of HIFU Preclinical Studies: An In Vivo Study.

Archive ouverte | N'Djin, William Apoutou | CCSD

International audience. To date, the efficacy of ablative technologies such as HIFU for the treatment of liver tumors in humans has been studied in animal models without tumors or in small animals like rats and rabb...

Toric HIFU Transducer for Large Thermal Ablation.

Archive ouverte | Melodelima, David | CCSD

International audience. A new geometry of High Intensity Focused Ultrasound (HIFU) transducer is described to enlarge the coagulated volume and decrease treatments time. Eight transducer elements and their quarter-w...

Chargement des enrichissements...