Visualization of calcium phosphate cement in teeth by zero echo time 1 H MRI at high field

Archive ouverte

Dou, Weiqiang | Mastrogiacomo, Simone | Veltien, Andor | Alghamdi, Hamdan | Walboomers, X. Frank | Heerschap, Arend

Edité par CCSD ; Wiley -

International audience. 1 H magnetic resonance imaging (MRI) by a zero echo time (ZTE) sequence is an excellent method to image teeth. Calcium phosphate cement (CPC) materials are applied in the restoration of tooth lesions, but it has not yet been investigated whether they can be detected by computed tomography (CT) or MRI. The aim of this study was to optimize high‐field ZTE imaging to enable the visualization of a new CPC formulation implanted in teeth and to apply this in the assessment of its decomposition in vivo . CPC was implanted in three human and three goat teeth ex vivo and in three goat teeth in vivo . An ultrashort echo time (UTE) sequence with multiple flip angles and echo times was applied at 11.7 T to measure T 1 and T 2 * values of CPC, enamel and dentin. Teeth with CPC were imaged with an optimized ZTE sequence. Goat teeth implanted with CPC in vivo were imaged after 7 weeks ex vivo. T 2 * relaxation of implanted CPC, dentin and enamel was better fitted by a model assuming a Gaussian rather than a Lorentzian distribution. For CPC and human enamel and dentin, the average T 2 * values were 273 ± 19, 562 ± 221 and 476 ± 147 μs, respectively, the average T 2 values were 1234 ± 27, 963 ± 151 and 577 ± 41 μs, respectively, and the average T 1 values were 1065 ± 45, 972 ± 40 and 903 ± 7 ms, respectively. In ZTE images, CPC had a higher signal‐to‐noise‐ratio than dentin and enamel because of the higher water content. Seven weeks after in vivo implantation, the CPC‐filled lesions showed less homogeneous structures, a lower T 1 value and T 2 * separated into two components. MRI by ZTE provides excellent contrast for CPC in teeth and allows its decomposition to be followed.

Consulter en ligne

Suggestions

Du même auteur

Bisphosphonate Functionalized Gadolinium Oxide Nanoparticles Allow Long‐Term MRI/CT Multimodal Imaging of Calcium Phosphate Bone Cement

Archive ouverte | Mastrogiacomo, Simone | CCSD

International audience. Abstract Direct in vivo monitoring of bioconstructs using noninvasive imaging modalities such as magnetic resonance imaging (MRI) or computed tomography (CT) is not possible for many material...

In vitro and in vivo assessment of a 3D printable gelatin methacrylate hydrogel for bone regeneration applications

Archive ouverte | Celikkin, Nehar | CCSD

International audience. Abstract Bone tissue engineering (BTE) has made significant progress in developing and assessing different types of bio‐substitutes. However, scaffolds production through standardized methods...

Perfluorocarbon/Gold Loading for Noninvasive in Vivo Assessment of Bone Fillers Using 19 F Magnetic Resonance Imaging and Computed Tomography

Archive ouverte | Mastrogiacomo, Simone | CCSD

International audience