Effective Orifice Area of Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Prostheses: An Echo Doppler Comparative Study

Archive ouverte

Kanso, Mohamad | Kibler, Marion | Hess, Sebastien | Rischner, Jérome | Plastaras, Philoktimon | Kindo, Michel | Hoang, Minh | de Poli, Fabien | Leddet, Pierre | Petit, Hélène | Zeyons, Floriane | Trinh, Annie | Matsushita, Kensuke | Morel, Olivier | Ohlmann, Patrick

Edité par CCSD ; MDPI -

International audience. Published data on the size-specific effective orifice area (EOA) of transcatheter heart valves (THVs) remain scarce. Here, we sought to investigate the intra-individual changes in EOA and mean transvalvular aortic gradient (MG) of the Sapien 3 (S3), CoreValve (CV), and Evolut R (EVR) prostheses both at short-term and at 1-year follow-up. The study sample consisted of 260 consecutive patients with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI). EOAs and MGs were measured with Doppler echocardiography for the following prostheses: S3 23 mm (n = 74; 28.5%), S3 26 mm (n = 67; 25.8%), S3 29 mm (n = 20; 7.7%), CV 23 mm (n = 2; 0.8%), CV 26 mm (n = 15; 5.8%), CV 29 mm (n = 24; 9.2%), CV 31 mm (n = 9; 3.5%), EVR 26 mm (n = 22; 8.5%), and EVR 29 mm (n = 27; 10.4%). Values were obtained at discharge, 1 month, 6 months, and 1 year from implantation. At discharge, EOAs were larger and MGs lower for larger-size prostheses, regardless of being balloon-expandable or self-expandable. In patients with small aortic annulus size, the hemodynamic performances of CV and EVR prostheses were superior to those of S3. However, we did not observe significant differences in terms of all-cause mortality according to THV type or size. Both balloon-expandable and self-expandable new-generation THVs show excellent hemodynamic performances without evidence of very early valve degeneration.

Suggestions

Du même auteur

Does Transcatheter Aortic Valve Replacement Modulate the Kinetic of Superoxide Anion Generation?

Archive ouverte | Marchandot, Benjamin | CCSD

Reactive oxygen species (ROS) are central bioenergetic markers linked to aortic stenosis (AS) development and severity. We sought to evaluate the time course and impact of ROS assessed by plasmatic superoxide anion (SA) among pati...

Paradoxical Increase of Stroke in Patients with Defect of High Molecular Weight Multimers of the von Willebrand Factors following Transcatheter Aortic Valve Replacement

Archive ouverte | Matsushita, Kensuke | CCSD

International audience. Abstract Background Stroke is a major cause of disability after transcatheter aortic valve replacement (TAVR) and stroke prediction models and data are crucially needed. Following TAVR, high ...

CT-ADP Point-of-Care Assay Predicts 30-Day Paravalvular Aortic Regurgitation and Bleeding Events following Transcatheter Aortic Valve Replacement

Archive ouverte | Kibler, Marion | CCSD

International audience. Background Paravalvular aortic regurgitation (PVAR) remains a frequent postprocedural concern following transcatheter aortic valve replacement (TAVR). Persistence of flow turbulence results i...

Chargement des enrichissements...