Artificial intelligence-based PET denoising could allow a two-fold reduction in [18F]FDG PET acquisition time in digital PET/CT

Archive ouverte

Weyts, Kathleen | Lasnon, Charline | Ciappuccini, Renaud | Lequesne, Justine | Corroyer-Dulmont, Aurélien | Quak, Elske | Clarisse, Bénédicte | Roussel, Laurent | Bardet, Stéphane | Jaudet, Cyril

Edité par CCSD ; Springer Verlag (Germany) [1976-....] -

CERVOXY. International audience. Purpose We investigated whether artificial intelligence (AI)-based denoising halves PET acquisition time in digital PET/CT. Methods One hundred ninety-five patients referred for [ 18 F]FDG PET/CT were prospectively included. Body PET acquisitions were performed in list mode. Original "PET90" (90 s/bed position) was compared to reconstructed ½-duration PET (45 s/bed position) with and without AI-denoising, "PET45AI and PET45". Denoising was performed by SubtlePET™ using deep convolutional neural networks. Visual global image quality (IQ) 3-point scores and lesion detectability were evaluated. Lesion maximal and peak standardized uptake values using lean body mass (SUL max and SUL peak), metabolic volumes (MV), and liver SUL mean were measured, including both standard and EARL 1 (European Association of Nuclear Medicine Research Ltd) compliant SUL. Lesion-to-liver SUL ratios (LLR) and liver coefficients of variation (CV liv) were calculated. Results PET45 showed mediocre IQ (scored poor in 8% and moderate in 68%) and lesion concordance rate with PET90 (88.7%). In PET45AI, IQ scores were similar to PET90 (P = 0.80), good in 92% and moderate in 8% for both. The lesion concordance rate between PET90 and PET45AI was 836/856 (97.7%), with 7 lesions (0.8%) only detected in PET90 and 13 (1.5%) exclusively in PET45AI. Lesion EARL 1 SUL peak was not significantly different between both PET (P = 0.09). Lesion standard SUL peak , standard and EARL1 SUL max , LLR and CV liv were lower in PET45AI than in PET90 (P < 0.0001), while lesion MV and liver SUL mean were higher (P < 0.0001). Good to excellent intraclass correlation coefficients (ICC) between PET90 and PET45AI were observed for lesion SUL and MV (ICC ≥ 0.97) and for liver SUL mean (ICC ≥ 0.87). Conclusion AI allows [ 18 F]FDG PET duration in digital PET/CT to be halved, while restoring degraded ½-duration PET image quality. Future multicentric studies, including other PET radiopharmaceuticals, are warranted.

Suggestions

Du même auteur

Deep Learning Denoising Improves and Homogenizes Patient [18F]FDG PET Image Quality in Digital PET/CT

Archive ouverte | Weyts, Kathleen | CCSD

CERVOXY. International audience. Given the constant pressure to increase patient throughput while respecting radiation protection, global body PET image quality (IQ) is not satisfactory in all patients. We first stu...

Upfront F18-choline PET/CT versus Tc99m-sestaMIBI SPECT/CT guided surgery in primary hyperparathyroidism: the randomized phase III diagnostic trial APACH2

Archive ouverte | Quak, Elske | CCSD

International audience. Background: The common endocrine disorder primary hyperparathyroidism (PHPT) can be cured by surgery. Preoperative localization of parathyroid adenoma (PTA) by imaging is a prerequisite for o...

The Impact of Artificial Intelligence CNN Based Denoising on FDG PET Radiomics

Archive ouverte | Jaudet, Cyril | CCSD

CERVOXY. International audience. Background: With a constantly increasing number of diagnostic images performed each year, Artificial Intelligence (AI) denoising methods offer an opportunity to respond to the growin...

Chargement des enrichissements...