Fluctuating Hearing Loss in the Only Hearing Ear: Cochlear Implantation in the Contralateral Deaf Side

Archive ouverte

Mosnier, Isabelle | Mathias, Nathalie | Flament, Jonathan | Amar, Dorith | Liagre-Callies, Amelie | Borel, Stéphanie | Ambert-Dahan, Emmanuèle | Sterkers, Olivier | Bernardeschi, Daniele | Gatignol, Peggy | Smail, Mustapha | Monin, Marie‐lorraine | Ewenczyk, Claire | Bouccara, Didier | Durr, Alexandra | Russo, Francesca Yoshie | de Seta, Daniele | Lahlou, Ghizlene | Nguyen, Yann

Edité par CCSD ; American Medical Association -

International audience. Objective To investigate the hearing performance of adult patients presenting unilateral deafness with contralateral fluctuating hearing loss who received a cochlear implant on the deaf side. Study Design Case series with chart review. Setting University tertiary referral center. Subjects and Methods Preoperatively and at 6 and 12 months postoperatively, 23 patients underwent pure tone audiometry and speech audiometry with disyllabic and monosyllabic words in a quiet environment and sentences in quiet and noisy (signal-to-noise ratio +10 dB SPL) environments under best-aided conditions. The Abbreviated Profile of Hearing Aid Benefit (APHAB) inventory was evaluated preoperatively and at 6 and 12 months postoperatively. Results No difference was found between pre- and postoperative tests for disyllabic and monosyllabic words. For sentences in quiet and noisy environments, a difference between pre- and postoperative performance was present at 1 year ( P = .002 and P = .02, respectively). In a noisy environment, a difference was present at 6 and 12 months postoperatively as compared with the preoperative value (mean ± SD: 6 months: 42% ± 7.1% vs 61% ± 6.5%, P = .016). A significant improvement in the APHAB score was found at 6 and 12 months postimplantation (Friedman’s 2-way analysis of variance by ranks, P < .001). The number of years of hearing deprivation of the deaf ear was not correlated with performance. Conclusion When incapacitating fluctuating hearing loss occurs in patients presenting a contralateral deaf ear, a cochlear implant is indicated in the latter ear, significantly improving performance in noisy conditions and allowing a better quality of communication to be achieved.

Consulter en ligne

Suggestions

Du même auteur

Benefit of the UltraZoom beamforming technology in noise in cochlear implant users

Archive ouverte | Mosnier, Isabelle | CCSD

International audience. The objectives of the study were to demonstrate the audiological and subjective benefits of the adaptive UltraZoom beamforming technology available in the Naída CI Q70 sound processor, in coc...

Benefits of a contralateral routing of signal device for unilateral Naída CI cochlear implant recipients

Archive ouverte | Mosnier, Isabelle | CCSD

International audience. PURPOSE : Many bilaterally deaf adults are only able to receive one cochlear implant (CI), resulting in suboptimal listening performance, especially in challenging listening environments. Add...

Meniett device in Meniere disease: Randomized, double-blind, placebo-controlled multicenter trial

Archive ouverte | Russo, Francesca Yoshie | CCSD

International audience. Objective: To evaluate the efficacy of portable Meniett low-pressure pulse generator (Medtronic Xomed, Jacksonville, FL) in Meniere disease.Study Design: Randomized, double-blind, placebo-con...

Chargement des enrichissements...