Agreement Between 2-Dimensional Shear Wave and Transient Elastography Values for Diagnosis of Advanced Chronic Liver Disease

Archive ouverte

Cassinotto, Christophe | Lapuyade, Bruno | Guiu, Boris | Marraud Des Grottes, Hortense | Piron, Lauranne | Merrouche, Wassil | Irles-Depe, Marie | Molinari, Nicolas | de Ledinghen, Victor

Edité par CCSD ; WB Saunders -

International audience. Background & aims: Inter-platform variation in liver stiffness evaluation (LSE) could hinder dissemination and clinical implementation of new ultrasound methods. We aimed to determine whether measurements of liver stiffness by bi-dimensional shear wave elastography (2D-SWE) with a Supersonic Imagine apparatus are comparable to those made by vibration-controlled transient elastography (VCTE).Methods: We collected data from 1219 consecutive patients with chronic liver disease who underwent LSE by VCTE and 2D-SWE (performed by blinded operators), on the same day, at a single center in France from September 2011 through June 2019. We assessed the ability of liver stiffness value distributions and 2D-SWE performances to identify patients with compensated advanced chronic liver disease (cACLD) according to the Baveno VI criteria, based on VCTE cut-off values.Results: VCTE and 2D-SWE values correlated (Pearson's correlation coefficient, 0.882; P < .0001; Lin concordance coefficient, 0.846; P < .0001). The median stiffness values were 6.7 kPa with VCTE (interquartile range, 4.8-11.6 kPa) and 7.1 kPa with 2D-SWE (interquartile range, 5.4-11.1 kPa) (P = .736). 2D-SWE values were slightly higher in the low percentiles and lower in the high percentiles; the best match with VCTE values were at approximately 7-9 kPa. The area under the curve of 2D-SWE for identifying of VCTE values below 10 was 0.964 (95% CI, 0.952-0.976) and for VCTE values above 15 kPa was 0.976 (95% CI, 0.963-0.988), with Youden index-associated cut-off values of 9.5 and 13kPa and best accuracy cut-off values of 10 kPa and 14 kPa, respectively. A 2D-SWE cut-off value of 10 kPa detected VCTE values below 10k Pa with 92% sensitivity, 87% specificity, and 91% accuracy.Conclusions: Measurement of liver stiffness by VCTE or 2D-SWE produces comparable results. 2D-SWE accurately identifies patients with cACLD according to the Baveno VI criteria based on VCTE cut-off values. A 10 kPa 2D-SWE cut-off value can be used to rule out cACLD.

Suggestions

Du même auteur

Transient Versus 2‐Dimensional Shear‐Wave Elastography in a Multistep Strategy to Detect Advanced Fibrosis in NAFLD

Archive ouverte | Cassinotto, Christophe | CCSD

International audience. The combination of laboratory and elastography tests allows the accurate diagnosis of advanced liver fibrosis in patients with nonalcoholic fatty liver disease (NAFLD). In this study, we comp...

Quantification of liver fat content in liver and primary liver lesions using triple-echo-gradient-echo MRI

Archive ouverte | Nougaret, Stephanie | CCSD

International audience. Objectives: To quantify and compare the fat fraction of background liver and primary liver lesions using a triple-echo-gradient-echo sequence. M&M: This IRB-approved study included 128 consec...

Deportalization, Venous Congestion, Venous Deprivation: Serial Measurements of Volumes and Functions on Morphofunctional 99mTc-Mebrofenin SPECT-CT

Archive ouverte | Piron, Lauranne | CCSD

International audience. The objective was to assess the changes in regional volumes and functions under venous-impaired vascular conditions following liver preparation. Twelve patients underwent right portal vein em...

Chargement des enrichissements...