French population exposure to ionizing radiation from diagnostic medical procedures in 2007

Archive ouverte

Etard, C. | Sinno-Tellier, S. | Empereur-Bissonnet, P. | Aubert, B.

Edité par CCSD ; Lippincott, Williams & Wilkins -

International audience. The objective of this study was to update the 2002 data on medical exposure of the French population to ionizing radiation. It is based on 2007 data and only includes exposures from diagnostic procedures conventional radiology, computed tomography, nuclear medicine, and diagnostic interventional radiology. Relevant data concerning the nature and frequencies of the examinations were obtained from two main sources the national health insurance data for private practice and representative surveys in public hospitals for public practice. An "average" effective dose was assessed for each type of examination using principally dosimetric data collected to update the French diagnostic reference levels and professional guidance. The results showed that 74.6 million examinations were performed in 2007, leading to an average effective dose per inhabitant equal to 1.3 mSv per year. Conventional radiology and CT represented 63% and 10.1% of the examinations and 26.1% and 58.0% of the effective dose, respectively. The annual number of examinations per inhabitant was constant between 2002 and 2007 (about 1.2 examinations). However, the corresponding average effective dose per inhabitant increased by 57%, from 0.83 to 1.3 mSv per year. This increased dose was due mostly to a growing number of CT and nuclear medicine examinations. As recommended by the European Commission, studies should be conducted every 5 y to survey the evolution of medical exposure of the French population. Furthermore, specific studies should be conducted to evaluate whether this estimated increase in dose delivered for diagnostics is related to an increase in the medical benefit. Copyright © 2012 Health Physics Society.

Consulter en ligne

Suggestions

Du même auteur

Establishment of diagnostic reference levels in cardiac ct in france A need for patient dose optimisation

Archive ouverte | Mafalanka, F. | CCSD

International audience. The objective of this study was to propose diagnostic reference levels (DRLs) for coronary computed tomography angiography (CCTA), in the context of a large variability in patient radiation d...

National survey of patient doses from whole-body FDG PET-CT examinations in france in 2011

Archive ouverte | Etard, C. | CCSD

International audience. A national survey of patient doses from 'whole-body PET-CT' examinations was conducted within all French nuclear medicine departments in 2011. Data related to injected [18F]-fluorodeoxyglucos...

Characterization of MOSFET detectors for in vivo dosimetry in interventional radiology and for dose reconstruction in case of overexposure

Archive ouverte | Bassinet, C. | CCSD

International audience. As MOSFET (Metal Oxide Semiconductor Field Effect Transistor) detectors allow dose measurements in real time, the interest in these dosimeters is growing. The aim of this study was to investi...