Embolism resistance of conifer roots can be accurately measured with the flow-centrifuge method

Archive ouverte

Bouche, Pauline S. | Jansen, Steven | Cochard, Hervé, H. | Burlett, Régis, R. | Capdeville, Gaëlle | Delzon, Sylvain, S.

Edité par CCSD ; INRA Science and Impact -

International audience. Resistance to embolism of conifer branches has commonly been studied with the flow-centrifuge technique (Cavitron) to carry out routine measurements. The aim of this study was to test the accuracy of the Cavitron for measurements on conifer roots. Based on earlier findings, it was suggested that the application of the flow-centrifuge technique to roots may not be free from artefacts due to potential torus aspiration when the pressure gradient between the sample ends is high. Here, three different protocols were used to obtain vulnerability curves in Pinus pinaster and Pseudotsuga menziesii roots: no water pressure gradient, and low and high water pressure gradient. In addition water extraction curves were obtained to only estimate the water released from conduits by embolism. Water extraction curves showed no water release caused by embolism before -1.3 and -2.5 MPa for P. pinaster and P. menziesii, respectively. The results illustrated discrepancies between these protocols: roots measured with the high and low pressure gradient protocols appeared erroneously more vulnerable to embolism than roots measured with no pressure gradient. In addition, pit anatomical observations of roots showed non-punctured tori and a high flexibility of the margo, which may increase the risk of torus aspiration. All together these results suggest that the early loss of hydraulic conductivity observed for the low and high pressure gradient protocols was not due to embolism but rather to a torus aspiration artefact when the pressure gradient is too high. We conclude that the no pressure gradient protocol provides a suitable method and that high vulnerability to embolism reported in previous studies for conifer roots should be interpreted with caution in the light of our findings.

Suggestions

Du même auteur

Low intra-tree variability in resistance to embolism in four Pinaceae species

Archive ouverte | Bouche, Pauline S. | CCSD

International audience. Key messageVariability of embolism resistance within individual trees was assessed in four Pinaceae species by using a single method of measurement: the Cavitron. Contrary to what has been pr...

Embolism resistance of conifer roots can be accurately measured with the flow-centrifuge method

Archive ouverte | Bouche, Pauline S | CCSD

International audience. Resistance to embolism of conifer branches has commonly been studied with the flow-centrifuge technique (Cavitron) to carry out routine measurements. The aim of this study was to test the acc...

Are needles of Pinus pinaster more vulnerable to xylem embolism than branches? New insights from X-ray computed tomography

Archive ouverte | Bouche, Pauline S. | CCSD

International audience. Plants can be highly segmented organisms with an independently redundant design of organs. In the context of plant hydraulics, leaves may be less embolism resistant than stems, allowing hydra...

Chargement des enrichissements...