A Retrospective Multicenter Study Comparing Speech Perception Outcomes for Bilateral Implantation and Bimodal Rehabilitation

Archive ouverte

Blamey, Peter | Maat, Bert | Başkent, Deniz | Mawman, Deborah | Burke, Elaine | Dillier, Norbert | Beynon, Andy | Kleine-Punte, Andrea | Govaerts, Paul | Skarzynski, Piotr | Huber, Alexander, W. | Sterkers-Artieres, Françoise | van de Heyning, Paul | O'Leary, Stephen | Fraysse, Bernard | Green, Kevin | Sterkers, Olivier | Venail, Frederic | Skarzynski, Henryk | Vincent, Christophe | Truy, Eric | Dowell, Richard | Bergeron, François | Lazard, Diane, S.

Edité par CCSD ; Lippincott, Williams & Wilkins -

International audience. OBJECTIVES:To compare speech perception outcomes between bilateral implantation (cochlear implants [CIs]) and bimodal rehabilitation (one CI on one side plus one hearing aid [HA] on the other side) and to explore the clinical factors that may cause asymmetric performances in speech intelligibility between the two ears in case of bilateral implantation.DESIGN:Retrospective data from 2247 patients implanted since 2003 in 15 international centers were collected. Intelligibility scores, measured in quiet and in noise, were converted into percentile ranks to remove differences between centers. The influence of the listening mode among three independent groups, one CI alone (n = 1572), bimodal listening (CI/HA, n = 589), and bilateral CIs (CI/CI, n = 86), was compared in an analysis taking into account the influence of other factors such as duration of profound hearing loss, age, etiology, and duration of CI experience. No within-subject comparison (i.e., monitoring outcome modifications in CI/HA subjects becoming CI/CI) was possible from this dataset. Further analyses were conducted on the CI/CI subgroup to investigate a number of factors, such as implantation side, duration of hearing loss, amount of residual hearing, and use of HAs that may explain asymmetric performances of this subgroup.RESULTS:Intelligibility ranked scores in quiet and in noise were significantly greater with both CI/CI and CI/HA than with a CI-alone group, and improvement with CI/CI (+11% and +16% in quiet and in noise, respectively) was significantly better than with CI/HA (+6% and +9% in quiet and in noise, respectively). From the CI/HA group, only subjects with ranked preoperative aided speech scores >60% performed as well as CI/CI participants. Furthermore, CI/CI subjects displayed significantly lower preoperative aided speech scores on average compared with that displayed by CI/HA subjects. Routine clinical data available from the present database did not explain the asymmetrical results of bilateral implantation.CONCLUSIONS:This retrospective study, based on basic speech audiometry (no lateralization cues), indicates that, on average, a second CI is likely to provide slightly better postoperative speech outcome than an additional HA for people with very low preoperative performance. These results may be taken into consideration to refine surgical indications for CIs.

Consulter en ligne

Suggestions

Du même auteur

Cochlear Implantation and Other Treatments in Single-Sided Deafness and Asymmetric Hearing Loss: Results of a National Multicenter Study Including a Randomized Controlled Trial

Archive ouverte | Marx, Mathieu | CCSD

International audience. Introduction: Cochlear implantation is a recent approach proposed to treat single-sided deafness (SSD) and asymmetric hearing loss (AHL). Several cohort studies showed its effectiveness on ti...

Benefit of the Vibrant Soundbridge device in patients implanted for 5 to 8 years.

Archive ouverte | Mosnier, Isabelle | CCSD

International audience. OBJECTIVES: To assess audiological performance, satisfaction rate, and side effects of 100 patients who have been using the middle ear implant Vibrant Soundbridge (VSB) for 5 to 8 yr when com...

Quality standards for bone conduction implants

Archive ouverte | Gavilan, Javier | CCSD

International audience. CONCLUSION: Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used...

Chargement des enrichissements...