Diagnostic value and relative weight of sequence-specific magnetic resonance features in characterizing clinically significant prostate cancers

Archive ouverte

Rouvière, Olivier | Dagonneau, Tristan | Cros, F. | Bratan, F. | Roche, Laurent | Mege-Lechevallier, F. | Ruffion, A. | Crouzet, S. | Colombel, M. | Rabilloud, Muriel

Edité par CCSD ; Public Library of Science -

International audience. Purpose: To assess the diagnostic weight of sequence-specific magnetic resonance features in characterizing clinically significant prostate cancers (csPCa).Materials and methods: We used a prospective database of 262 patients who underwent T2-weighted, diffusion-weighted, and dynamic contrast-enhanced (DCE) imaging before prostatectomy. For each lesion, two independent readers (R1, R2) prospectively defined nine features: shape, volume (V_Max), signal abnormality on each pulse sequence, number of pulse sequences with a marked (S_Max) and non-visible (S_Min) abnormality, likelihood of extracapsular extension (ECE) and PSA density (dPSA). Overall likelihood of malignancy was assessed using a 5-level Likert score. Features were evaluated using the area under the receiver operating characteristic curve (AUC). csPCa was defined as Gleason ≥7 cancer (csPCa-A), Gleason ≥7(4+3) cancer (csPCa-B) or Gleason ≥7 cancer with histological extraprostatic extension (csPCa-C),Results: For csPCa-A, the Signal1 model (S_Max+S_Min) provided the best combination of signal-related variables, for both readers. The performance was improved by adding V_Max, ECE and/or dPSA, but not shape. All models performed better with DCE findings than without.When moving from csPCa-A to csPCa-B and csPCa-C definitions, the added value of V_Max, dPSA and ECE increased as compared to signal-related variables, and the added value of DCE decreased.For R1, the best models were Signal1+ECE+dPSA (AUC = 0,805 [95%CI:0,757–0,866]), Signal1+V_Max+dPSA (AUC = 0.823 [95%CI:0.760–0.893]) and Signal1+ECE+dPSA [AUC = 0.840 (95%CI:0.774–0.907)] for csPCa-A, csPCA-B and csPCA-C respectively. The AUCs of the corresponding Likert scores were 0.844 [95%CI:0.806–0.877, p = 0.11], 0.841 [95%CI:0.799–0.876, p = 0.52]) and 0.849 [95%CI:0.811–0.884, p = 0.49], respectively.For R2, the best models were Signal1+V_Max+dPSA (AUC = 0,790 [95%CI:0,731–0,857]), Signal1+V_Max (AUC = 0.813 [95%CI:0.746–0.882]) and Signal1+ECE+V_Max (AUC = 0.843 [95%CI: 0.781–0.907]) for csPCa-A, csPCA-B and csPCA-C respectively. The AUCs of the corresponding Likert scores were 0. 829 [95%CI:0.791–0.868, p = 0.13], 0.790 [95%CI:0.742–0.841, p = 0.12]) and 0.808 [95%CI:0.764–0.845, p = 0.006]), respectively.Conclusion: Combination of simple variables can match the Likert score’s results. The optimal combination depends on the definition of csPCa.

Suggestions

Du même auteur

Quantitative Analysis of Prostate Multiparametric MR Images for Detection of Aggressive Prostate Cancer in the Peripheral Zone: A Multiple Imager Study

Archive ouverte | Hoang, Dinh A. | CCSD

International audience. Purpose To assess the intermanufacturer variability of quantitative models in discriminating cancers with a Gleason score of at least 7 among peripheral zone (PZ) lesions seen at 3-T multipar...

Value of prostate multiparametric magnetic resonance imaging for predicting biopsy results in first or repeat biopsy

Archive ouverte | Habchi, H. | CCSD

International audience

Variability induced by the MR imager in dynamic contrast-enhanced imaging of the prostate

Archive ouverte | Brunelle, S. | CCSD

International audience. PURPOSE:To evaluate the variability induced by the imager in discriminating high-grade (Gleason≥7) prostate cancers (HGC) using dynamic contrast-enhanced MRI.MATERIAL AND METHODS:We retrospec...

Chargement des enrichissements...