Dose reduction with iterative reconstruction in multi-detector CT: What is the impact on deformation of circular structures in phantom study?

Archive ouverte

Greffier, J. | Macri, F. | Larbi, A. | Fernandez, A. | Pereira, F. | Mekkaoui, C. | Beregi, J.-P.

Edité par CCSD ; Elsevier -

International audience. OBJECTIVES:To evaluate the distortion of circular structures induced by the increased image noise related to dose reduction and to assess the effect of iterative reconstruction (IR).METHODS:MDCT acquisitions were performed with 120 kVp for 200/100/60/40/20mAs with 100%/50%/30%/20%/10% of dose. Raw data were reconstructed by filtered back projection (FBP) and with two IR strengths. Image quality indices referred to water and acrylic were measured on a quality image phantom. Areas, perimeters, circularity were measured on the circular inserts of 4.8, 7.9 and 11.1mm on a morphological phantom.RESULTS:Dose reduction resulted in increased image noise and in decreased signal to noise ratio and contrast to noise ratio. IR improved these indices for the same dose without affecting the signal (number CT) and spatial resolution (modulation transfer function). The values of area, perimeter and circularity were altered compared to the actual value and the inserts were visually deformed with the dose reduction. IR improved these three parameters. Image quality indices, areas, perimeters and circularity of inserts were similar between the acquisition at 100% of the dose in FBP, 50% in strength-3 and 30% in strength-5 with different curves of noise power spectrum.CONCLUSION:IR associated to 70% of dose reduction modifies the images smooth (NPS) but maintains adequate image quality indices without causing distortions of circular structures.

Consulter en ligne

Suggestions

Du même auteur

Dose reduction with iterative reconstruction: Optimization of CT protocols in clinical practice

Archive ouverte | Greffier, J. | CCSD

International audience. OBJECTIVES:To create an adaptable and global approach for optimizing MDCT protocols by evaluating the influence of acquisition parameters and Iterative Reconstruction (IR) on dose reduction a...

Diagnostic performance of a low dose triple rule-out CT angiography using SAFIRE in emergency department

Archive ouverte | Si-Mohamed, S. | CCSD

International audience. OBJECTIVES: To compare the diagnostic performance of "triple rule out" CT angiography (TRO-CTA) at 100kVp using sinogram affirmed iterative reconstruction (SAFIRE) with TRO-CTA at 120kVp usin...

Detection and characterization of focal liver lesions with ultra-low dose computed tomography in neoplastic patients

Archive ouverte | Larbi, A. | CCSD

International audience. PURPOSE: The purpose of this study was to evaluate and compare the diagnostic accuracy of ultra-low dose (ULD) computed tomography (CT) with that of standard dose (STD) CT in the detection an...

Chargement des enrichissements...