Analysis of plasticizers in PVC medical devices: performance comparison of eight analytical methods.

Archive ouverte

Bernard, L. | Bourdeaux, D. | Pereira, B. | Azaroual, N. | Barthélémy, C. | Breysse, C. | Chennell, P. | Cueff, R. | Dine, T. | Eljezi, T. | Feutry, F. | Genay, S. | Kambia, N. | Lecoeur, M. | Masse, M. | Odou, P. | Radaniel, T. | Simon, N. | Vaccher, C. | Verlhac, C. | Yessaad, M. | Décaudin, B. | Sautou, V.

Edité par CCSD ; Elsevier -

International audience. A wide variety of medical devices (MDs) used in hospitals are made of flexible plasticized polyvinylchloride (PVC). Different plasticizers are present in variable amounts in the PVC matrix of the devices and can leach out into the infused solutions and may enter into contact with the patients. The ARMED1 project aims to assess the migration of these plasticizers from medical devices and therefore the level of exposure in patients. For the first task of the project, eight methods were developed to directly detect and quantify the plasticizers in the PVC matrix of the MDs. We compared the overall performances of the analytical methods using standardized and validated criteria in order to provide the scientific community with the guidance and the technical specifications of each method for the intended application. We have shown that routine rapid screening could be performed directly on the MDs using the FTIR technique, with cost-effective analyses. LC techniques may also be used, but with limits and only with individual quantification of the main plasticizers expected in the PVC matrix. GC techniques, especially GC–MS, are both more specific and more sensitive than other techniques. NMR is a robust and specific technique to precisely discriminate all plasticizers in a MD but is limited by its cost and its low ability to detect and quantify plasticizer contamination, e.g. by DEHP. All these results have been confirmed by a real test, called the " blind test " carried out on 10 MD samples.

Consulter en ligne

Suggestions

Du même auteur

Migrability of PVC plasticizers from medical devices into a simulant of infused solutions

Archive ouverte | Bernard, L. | CCSD

International audience

A proof of principle study using radiopharmaceuticals to quantify and localize container-content interactions in medical syringes

Archive ouverte | Dupire, C. | CCSD

International audience. The sorption of drugs onto their contents is a known phenomenon that is difficult to analyse precisely. The purpose of this study was to present a non-invasive method for locating and quantif...

Minimizing interaction risks between medications and infusion tubings: how much do materials come into play?

Archive ouverte | Tokhadze, N. | CCSD

International audience

Chargement des enrichissements...