2-D Ultrasound Sparse Arrays Multidepth Radiation Optimization Using Simulated Annealing and Spiral-Array Inspired Energy Functions

Archive ouverte

Roux, Emmanuel | Ramalli, Alessandro | Tortoli, Piero | Cachard, Christian | Robini, Marc C. | Liebgott, Hervé

Edité par CCSD ; Institute of Electrical and Electronics Engineers -

International audience. Full matrix arrays are excellent tools for 3-D ultrasound imaging, but the required number of active elements is too high to be individually controlled by an equal number of scanner channels. The number of active elements is significantly reduced by the sparse array techniques, but the position of the remaining elements must be carefully optimized. This issue is faced here by introducing novel energy functions in the simulated annealing (SA) algorithm. At each iteration step of the optimization process, one element is freely translated and the associated radiated pattern is simulated. To control the pressure field behavior at multiple depths, three energy functions inspired by the pressure field radiated by a Blackman-tapered spiral array are introduced. Such energy functions aim at limiting the main lobe width while lowering the side lobe and grating lobe levels at multiple depths. Numerical optimization results illustrate the influence of the number of iterations, pressure measurement points, and depths, as well as the influence of the energy function definition on the optimized layout. It is also shown that performance close to or even better than the one provided by a spiral array, here assumed as reference, may be obtained. The finite-time convergence properties of SA allow the duration of the optimization process to be set in advance.

Consulter en ligne

Suggestions

Du même auteur

Wideband 2-D Array Design Optimization With Fabrication Constraints for 3-D US Imaging

Archive ouverte | Roux, Emmanuel | CCSD

International audience. Ultrasound (US) 2-D arrays are of increasing interest due to their electronic steering capability to investigate 3-D regions without requiring any probe movement. These arrays are typically p...

Comparison of different optimized irregular sparse 2D ultrasound arrays

Archive ouverte | Diarra, Bakary | CCSD

International audience. The role of 2D matrix arrays in the realization of real time 3D ultrasound imaging is crucial as the latter permit to acquire a complete volume. The lack of control systems for these arrays c...

Plane-Wave Transverse Oscillation for High-Frame-Rate 2-D Vector Flow Imaging

Archive ouverte | Lenge, Matteo | CCSD

International audience. Transverse oscillation (TO) methods introduce oscillations in the pulse–echo field (PEF) along the direction transverse to the ultrasound propagation direction. This may be exploited to exten...