Electrocardiographic correlates of mechanical dyssynchrony in recipients of cardiac resynchronization therapy devices

Archive ouverte

Mabo, Philippe | Daubert, Claude | Behaghel, Albin | Brunet-Bernard, Anne | Oger, Emmanuel | Martins, Raphael | Donal, Erwan | Fournet, Maxime | Feneon, Damien | Leclercq, Christophe

Edité par CCSD ; Elsevier ; Société française de cardiologie [2008-....] -

International audience. Background The relationship between electrical and mechanical indices of cardiac dyssynchronization in systolic heart failure (HF) remains poorly understood. Objectives We examined retrospectively this relationship by using the daily practice tools in cardiology in recipients of cardiac resynchronization therapy (CRT) systems. Methods We studied 119 consecutive patients in sinus rhythm and QRS ≥ 120 ms (mean: 160 ± 17 ms) undergoing CRT device implantation. P wave duration, PR, ePR (end of P wave to QRS onset), QT, RR–QT, JT and QRS axis and morphology were putative predictors of atrioventricular (diastolic filling time [DFT]/RR), interventricular mechanical dyssynchrony (IVMD) and left intraventricular mechanical dyssynchrony (left ventricular pre-ejection interval [PEI] and other measures) assessed by transthoracic echocardiography (TTE). Correlations between TTE and electrocardiographic measurements were examined by linear regression. Results Statistically significant but relatively weak correlations were found between heart rate (r = −0.5), JT (r = 0.3), QT (r = 0.3), RR–QT intervals (r = 0.5) and DFT/RR, though not with PR and QRS intervals. Weak correlations were found between: (a) QRS (r = 0.3) and QT interval (r = 0.3) and (b) IVMD > 40 ms; and between (a) ePR (r = −0.2), QRS (r = 0.4), QT interval (r = 0.3) and (b) LVPEI, though not with other indices of intraventricular dyssynchrony. Conclusions The correlations between electrical and the evaluated mechanical indices of cardiac dyssynchrony were generally weak in heart failure candidates for CRT. These data may help to explain the discordance between electrocardiographic and echocardiographic criteria of ventricular dyssynchrony in predicting the effect of CRT

Consulter en ligne

Suggestions

Du même auteur

Left atrial function, a new predictor of response to cardiac resynchronization therapy?. Left atrial function, a new predictor of response to cardiac resynchronization therapy?: Left atrium and resynchronization

Archive ouverte | Feneon, Damien | CCSD

International audience. Background - Cardiac resynchronization therapy (CRT) improves left ventricular (LV) function and induces LV remodeling, and it is an established therapy for advanced heart failure with prolon...

0346 : Procedural safety and long-term follow-up after pacemaker implantation in nonagenarians

Archive ouverte | Loirat, Aurelie | CCSD

International audience. Introduction The rate of pacemaker(PM) implantations is continuously growing. A large number of nonagenarian patients will be implanted in the future. We aimed at analyzing the outcome after ...

0344 : Pacemaker replacement in nonagenarians: procedural safety and long-term follow-up

Archive ouverte | Loirat, Aurelie | CCSD

International audience. Background The rate of pacemaker (PM) implantations is continuously growing. A large number of elderly patients is expected to be implanted in the future. We aimed at analyzing the short and ...

Chargement des enrichissements...