A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation

Archive ouverte

Zhao, Huaying | Ghirlando, Rodolfo | Alfonso, Carlos | Arisaka, Fumio | Attali, Ilan | Bain, David L | Bakhtina, Marina M | Becker, Donald F | Bedwell, Gregory J | Bekdemir, Ahmet | Besong, Tabot M D | Birck, Catherine | Brautigam, Chad A | Brennerman, William | Byron, Olwyn | Bzowska, Agnieszka | Chaires, Jonathan B | Chaton, Catherine T | Cölfen, Helmut | Connaghan, Keith D | Crowley, Kimberly A | Curth, Ute | Daviter, Tina | Dean, William L | Díez, Ana I | Ebel, Christine | Eckert, Debra M | Eisele, Leslie E | Eisenstein, Edward | England, Patrick | Escalante, Carlos | Fagan, Jeffrey A | Fairman, Robert | Finn, Ron M | Fischle, Wolfgang | de La Torre, José García | Gor, Jayesh | Gustafsson, Henning | Hall, Damien | Harding, Stephen E | Cifre, José G Hernández | Herr, Andrew B | Howell, Elizabeth E | Isaac, Richard S | Jao, Shu-Chuan | Jose, Davis | Kim, Soon-Jong | Kokona, Bashkim | Kornblatt, Jack A | Kosek, Dalibor | Krayukhina, Elena | Krzizike, Daniel | Kusznir, Eric A | Kwon, Hyewon | Larson, Adam | Laue, Thomas M | Le Roy, Aline | Leech, Andrew P | Lilie, Hauke | Luger, Karolin | Luque-Ortega, Juan R | Ma, Jia | May, Carrie A | Maynard, Ernest L | Modrak-Wojcik, Anna | Mok, Yee-Foong | Mücke, Norbert | Nagel-Steger, Luitgard | Narlikar, Geeta J | Noda, Masanori | Nourse, Amanda | Obsil, Tomas | Park, Chad K | Park, Jin-Ku | Pawelek, Peter D | Perdue, Erby E | Perkins, Stephen J | Perugini, Matthew A | Peterson, Craig L | Peverelli, Martin G | Piszczek, Grzegorz | Prag, Gali | Prevelige, Peter E | Raynal, Bertrand D E | Rezabkova, Lenka | Richter, Klaus | Ringel, Alison E | Rosenberg, Rose | Rowe, Arthur J | Rufer, Arne C | Scott, David J | Seravalli, Javier G | Solovyova, Alexandra S | Song, Renjie | Staunton, David | Stoddard, Caitlin | Stott, Katherine | Strauss, Holger M | Streicher, Werner W | Sumida, John P | Swygert, Sarah G | Szczepanowski, Roman H | Tessmer, Ingrid | Toth, Ronald T | Tripathy, Ashutosh | Uchiyama, Susumu | Uebel, Stephan F W | Unzai, Satoru | Gruber, Anna Vitlin | von Hippel, Peter H | Wandrey, Christine | Wang, Szu-Huan | Weitzel, Steven E | Wielgus-Kutrowska, Beata | Wolberger, Cynthia | Wolff, Martin | Wright, Edward | Wu, Yu-Sung | Wubben, Jacinta M | Schuck, Peter

Edité par CCSD ; Public Library of Science -

International audience. Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.

Suggestions

Du même auteur

A multi-laboratory benchmark study of isothermal titration calorimetry (ITC) using Ca2+ and Mg2+ binding to EDTA

Archive ouverte | Velazquez-Campoy, Adrian | CCSD

International audience. A small-scale ITC benchmarking study was performed involving 9 biophysics laboratories/facilities, to evaluate interlaboratory and intra-laboratory basal levels of uncertainty. Our prime goal...

Reproducibility and accuracy of microscale thermophoresis in the NanoTemper Monolith: a multi laboratory benchmark study

Archive ouverte | López-Méndez, Blanca | CCSD

International audience. Microscale thermophoresis (MST), and the closely related Temperature Related Intensity Change (TRIC), are synonyms for a recently developed measurement technique in the field of biophysics to...

AUC and Small-Angle Scattering for Membrane Proteins.

Archive ouverte | Le Roy, Aline | CCSD

International audience. Analytical ultracentrifugation is a key tool to assess homogeneity of membrane protein samples, to determine protein association state and detergent concentration, and to characterize protein...

Chargement des enrichissements...