The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery.

Archive ouverte

Nguyen, Ba-Vinh | Vincent, Jean-Louis | Nowak, Emmanuel | Coat, Michelle | Paleiron, Nicolas | Gouny, Pierre | Ould-Ahmed, Mehdi | Guillouët, Maïté | Arvieux, Charles Christian | Gueret, Gildas

Edité par CCSD ; Lippincott, Williams & Wilkins -

International audience. BACKGROUND: In March 2008, a new multiwavelength pulse oximeter, the Radical 7 (Rad7; Masimo Corp., Irvine, CA), was developed that offers noninvasive measurement of hemoglobin concentration. Accuracy has been established in healthy adults and some surgical patients, but not in cardiac surgery intensive care patients, a group at high risk of postoperative bleeding events and anemia in whom early diagnosis could improve management. METHODS: In this prospective, observational study conducted in a cardiovascular intensive care unit, we compared hemoglobin concentrations shown by the Rad7 with arterial hemoglobin concentrations determined by an automated hematology analyzer, XE-2100 (Roche, Neuilly sur Seine, France). Two software versions of Rad7 (V 7.3.0.1 [42 points of comparison in 14 patients] and the updated V 7.3.1.1 [61 points of comparison in 27 patients]) were studied during two 1-week periods. Bias, defined as the difference between the 2 methods (Masimo SpHb-XE-2100 laboratory hemoglobin), was calculated. A negative bias indicated that the Masimo underestimated hemoglobin compared with the laboratory analyzer. Correlation between the perfusion index given by Rad7 and the hemoglobin bias was also studied. RESULTS: Correlations between Rad7 and XE-2100 were weak for both software versions (R2=0.11 for V 7.3.0.1 and R2=0.27 for V 7.3.1.1). Mean bias was -1.3 g/dL for V 7.3.0.1 and -1.7 g/dL for V 7.3.1.1, with wide 95% prediction intervals for the bias (respectively, -4.6 to 2.1 g/dL and -5.7 to 2.3 g/dL). The absolute hemoglobin bias tended to increase when the perfusion index decreased. For the V 7.3.0.1 software, the average absolute bias was 1.9 g/dL for perfusion index<2 and 0.8 g/dL for perfusion index>2 (P=0.03). For V 7.3.1.1, the mean absolute bias was 2.1 g/dL when the perfusion index was <2, and 1.6 g/dL when the perfusion index was >2 (P=0.26). CONCLUSIONS: Our study demonstrates poor correlation between hemoglobin measured noninvasively by multiwavelength pulse oximetry and a laboratory hematology analyzer. The difference was greater when the pulse oximetry perfusion index was low, as may occur in shock, hypothermia, or vasoconstriction patients. The multiwavelength pulse oximetry is not sufficiently accurate for clinical use in a cardiovascular intensive care unit.

Consulter en ligne

Suggestions

Du même auteur

Design and Evaluation of a Wireless Electrocardiogram Monitor in an Operating Room: A Pilot Study

Archive ouverte | Ariès, Philippe | CCSD

International audience. Wired electrocardiogram monitors are an important component of current perioperative monitoring. Wireless monitoring units could help reduce the number of cables attached to patients and thus...

The reproducibility of Stewart parameters for acid-base diagnosis using two central laboratory analyzers.

Archive ouverte | Nguyen, Ba-Vinh | CCSD

International audience. BACKGROUND: Acid-base derangements can be interpreted using the Stewart-Fencl approach, which includes calculation of the apparent strong ion difference (SID(app)), the effective SID (SID(eff...

Determination of the learning curve for ultrasound-guided jugular central venous catheter placement.

Archive ouverte | Nguyen, Ba-Vinh | CCSD

International audience. PURPOSE: Use of ultrasound (US) when introducing central venous catheters (CVC) may improve success rates, reduce the number of needle punctures, and decrease complication rates, but has been...

Chargement des enrichissements...