Setting epidemiological cut-off values relevant to MIC and disc diffusion data for Aeromonas salmonicida generated by a standard method

Archive ouverte

Smith, Peter | Buba, Elizabeth | Desbois, Andrew, P | Adams, Alexandra | Verner-Jeffreys, David | Joseph, Andrew | Light, Edel | Le Devendec, Laëtitia | Jouy, Eric | Larvor, Emeline | Boitard, Pierre-Marie | Jamin, Matthieu | Keck, Nicolas | Le Breton, Alain | Thuillier, Benoit | Ravaille, Christian | Morin, Thierry | Baron, Sandrine

Edité par CCSD ; Inter Research -

International audience. The Clinical and Laboratory Standards Institute has published epidemiological cut-off values for susceptibility data generated at 22°°C and read after 44-48 h for florfenicol, oxolinic acid and oxytetracycline against Aeromonas salmonicida. The cut-off values for the minimum inhibitory concentration (MIC) and disc diffusion were derived from data obtained by 1 laboratory and 2 laboratories respectively. The present work reports the generation of susceptibility data from additional laboratories and the calculation of provisional cut-off values from aggregations of these data with previously published data. With respect to MIC data, the provisional cut-off values, derived from aggregations of the data from 4 laboratories, were ≤4 µg ml-1 for florfenicol, ≤0.0625 µg ml-1 for oxolinic acid and ≤1 µg ml-1 for oxytetracycline. For disc diffusion data, the provisional cut-off values derived from aggregations of the data from 5 laboratories were ≥30 mm for florfenicol, ≥32 mm for oxolinic acid and ≥25 mm for oxytetracycline. In addition, a cut-off value of ≥29 mm for ampicillin was derived from the aggregation of data from 4 laboratories.

Suggestions

Du même auteur

Epidemiological cut-off values for Yersina ruckeri disc diffusion data generated by a standardised method

Archive ouverte | Smith, Peter | CCSD

International audience. In order to establish the meaning of data generated in antimicrobial agent susceptibility tests, it is necessary to develop internationally harmonised interpretive criteria. Currently, such c...

Epidemiological cut-off values for Vibrio anguillarum MIC and disc diffusion data generated by standardised methods

Archive ouverte | Smith, Peter | CCSD

International audience. This work aims to generate the data needed to set epidemiological cut-off values for minimum inhibitory concentration (MIC) and disc-diffusion zone measurements of Vibrio anguillarum. A total...

Agreement between the categorization of isolates of Aeromonas salmonicida and Yersinia ruckeri by disc diffusion and MIC tests performed at 22℃

Archive ouverte | Baron, Sandrine | CCSD

International audience. Standard disc diffusion and MIC test procedure were used to investigate the susceptibility of two hundred and fifty-one isolates collected from infected fish in France to florfenicol, oxolini...

Chargement des enrichissements...