Reliability and reproducibility of the DICART device to assess capillary refill time: a bench and in-silico study

Archive ouverte

Jacquet-Lagrèze, M. | Saint-Jean, C. | Bouët, T. | Reynaud, S. | Ruste, M. | Fellahi, J. L.

Edité par CCSD ; Springer Verlag -

International audience. Capillary refill time (CRT) is an important indicator of peripheral perfusion with a strong prognostic value, but it is sensitive to environmental factors and numerous measurement methods are reported in the litterature. DiCARTECH has developed a device that assesses CRT. We sought to investigate the robustness of the device and the reproducibility of the algorithm in a bench and in-silico study. We used the video acquired from a previous clinical study on healthy volunteers. For the bench study, the measurement process was performed by a robotic system piloted by a computer that analyzed 250 times nine previously acquired videos. For the in-silico study, we used 222 videos to test the algorithm's robustness. We created 30 videos from each video with a large blind spot and used the "color jitter" function to create a hundred videos from each video. In the bench study, the coefficient of variation was 11% (95%CI: 9-13). The correlation with human-measured CRT was good (R(2) = 0.91, P \textless 0.001). In the in-silico study, for the blind spotted video, the coefficient of variation was 13% (95%CI: 10-17). For the color-jitter modified video the coefficient of variation was 62% (95%CI: 55-70). We confirmed the ability of the DiCART™ II device to perform multiple measurements without mechanical or electronic dysfunction. The precision and reproducibility of the algorithm are compatible with the assessment of clinical small changes in CRT.

Consulter en ligne

Suggestions

Du même auteur

Fluids, vasopressors, and acute kidney injury after major abdominal surgery. Comment on Br J Anaesth 2022; 129: 317-26

Archive ouverte | Fellahi, J. L. | CCSD

International audience. No abstract available

Central Versus Peripheral Arterial Pressure Monitoring in Patients Undergoing Cardiac Surgery: A Prospective Observational Study

Archive ouverte | Jacquet-Lagrèze, M. | CCSD

International audience. OBJECTIVE: The aortic-to-radial arterial pressure gradient is described during and after cardiopulmonary bypass (CPB), and can lead to underestimating arterial blood pressure. The authors hyp...

Venoarterial Extracorporeal Membranous Oxygenation Should Be Considered as an Appropriate Rescue Therapy for Sepsis-Induced Refractory Cardiogenic Shock

Archive ouverte | Jacquemet, P. L. | CCSD

International audience. No abstract available

Chargement des enrichissements...