Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging.

Archive ouverte

Boussion, Nicolas | Cheze Le Rest, Catherine | Hatt, Mathieu | Visvikis, Dimitri

Edité par CCSD ; Springer Verlag (Germany) [1976-....] -

International audience. PURPOSE: Partial volume effects (PVEs) are consequences of the limited resolution of emission tomography. The aim of the present study was to compare two new voxel-wise PVE correction algorithms based on deconvolution and wavelet-based denoising. MATERIALS AND METHODS: Deconvolution was performed using the Lucy-Richardson and the Van-Cittert algorithms. Both of these methods were tested using simulated and real FDG PET images. Wavelet-based denoising was incorporated into the process in order to eliminate the noise observed in classical deconvolution methods. RESULTS: Both deconvolution approaches led to significant intensity recovery, but the Van-Cittert algorithm provided images of inferior qualitative appearance. Furthermore, this method added massive levels of noise, even with the associated use of wavelet-denoising. On the other hand, the Lucy-Richardson algorithm combined with the same denoising process gave the best compromise between intensity recovery, noise attenuation and qualitative aspect of the images. CONCLUSION: The appropriate combination of deconvolution and wavelet-based denoising is an efficient method for reducing PVEs in emission tomography.

Consulter en ligne

Suggestions

Du même auteur

Contrast enhancement in emission tomography by way of synergistic PET/CT image combination.

Archive ouverte | Boussion, Nicolas | CCSD

International audience. The display of image fusion is well accepted as a powerful tool in visual image analysis and comparison. In clinical practice, this is a mandatory step when studying images from a dual PET/CT...

A multiresolution image based approach for correction of partial volume effects in emission tomography.

Archive ouverte | Boussion, Nicolas | CCSD

International audience. Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography. They lead to a loss of signal in tissues of size similar to the point spread function ...

Evaluation of a 3D local multiresolution algorithm for the correction of partial volume effects in positron emission tomography.

Archive ouverte | Le Pogam, Adrien | CCSD

International audience. PURPOSE: Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography leading to underestimation of uptake in tissues of size similar to the point s...

Chargement des enrichissements...