Performance of penicillinase detection tests in Staphylococcus epidermidis: comparison of different phenotypic methods

Archive ouverte

Aubry, Benjamin | Lemarié, Carole | Chenouard, Rachel | Kempf, Marie | Eveillard, Matthieu | Pailhoriès, Hélène

Edité par CCSD ; BioMed Central -

International audience. BackgroundStaphylococcus epidermidis is the leading coagulase negative staphylococci (CoNS) species associated with healthcare associated infections. In order to de-escalate antimicrobial therapy, isolates of S. epidermidis lacking the blaZ gene should be eligible for targeted antimicrobial therapy. However, testing the susceptibility of coagulase negative staphylococci (CoNS) to penicillin G is no longer recommended by EUCAST, given the low performances for penicillinase detection in CoNS. The objective of this work was to determine a phenotypic method with high performance for detecting penicillinase production in S. epidermidis.ResultsFour techniques for the detection of penicillinase production (disk diffusion, zone edge test, nitrocefin test, Minimal Inhibitory Concentration (MIC) by automated system Vitek2®) were evaluated on 182 S. epidermidis isolates, using identification of blaZ gene by PCR as the reference method. The performance of the methods for penicillinase detection was compared by the sensitivity, the specificity, the negative predictive value and the positive predictive value, and with Cohen’s kappa statistical test. Among the 182 S. epidermidis included in this study, 55 carried the blaZ gene. The nitrocefin test, characterized by a poor sensitivity (91%), was therefore excluded from S. epidermidis penicillinase detection. The algorithm proposed here for the penicillinase detection in S. epidermidis involved two common antimicrobial susceptibility techniques: disk diffusion method and MIC by Vitek2® system. Disk diffusion method, interpreted with a 26 mm breakpoint for penicillin G, was associated with a high sensitivity (98%) and specificity (100%). This method was completed with zone edge test for S. epidermidis with penicillin G diameter from 26 to 35 mm (sensitivity of 98%). The Vitek2® system is associated with a low sensitivity (93%) and a high specificity (99%) This low sensitivity is associated with false negative results, in isolates with 0.12 mg/L Penicillin G MIC values and blaZ positive. Thus for penicillin G MIC of 0.06 mg/L or 0.12 mg/L, a second step with disc diffusion method is suggested.ConclusionsAccording to our results, the strategy proposed here allows the interpretation of penicillin G susceptibility in S. epidermidis isolates, with an efficient detection of penicillin G resistance.

Suggestions

Du même auteur

BIOFIRE® Blood Culture IDentification 2 (BCID2) panel for early adaptation of antimicrobial therapy in adult patients with bloodstream infections: a real-life experience

Archive ouverte | Donnars, Anne | CCSD

International audience. Our objective was to assess the effectiveness of a multiplex PCR panel for blood culture identification (BCID2) on the implementation of appropriate antimicrobial therapy. We conducted a mono...

Cerebral epidural empyema due to Bartonella henselae: a case report

Archive ouverte | Matta, Stéphanie | CCSD

International audience. Background: Cat scratch disease frequently involves a benign, self-limited disease. Neurological forms associated with Bartonella henselae are uncommon, consisting mostly in neuroretinitis, e...

Iterative fecal microbiota transplantations for eradicating digestive colonization with carbapenemase-producing Enterobacteriaceae: is it worth it?

Archive ouverte | Mahieu, Rafael | CCSD

International audience. Carbapenemase-producing Enterobacteriaceae (CPE) have emerged as a major source of bacterial resistance and their dissemination is a serious public health threat.1 It has also been demonstrat...

Chargement des enrichissements...