Feasibility and safety of ultra-low volume ventilation (≤ 3 ml/kg) combined with extra corporeal carbon dioxide removal (ECCO2R) in acute respiratory failure patients

Archive ouverte

Monet, Clément | Renault, Thomas | Aarab, Yassir | Pensier, Joris | Prades, Albert | Lakbar, Ines | Le Bihan, Clément | Capdevila, Mathieu | de Jong, Audrey | Molinari, Nicolas | Jaber, Samir

Edité par CCSD ; BioMed Central -

International audience. Background : Ultra-protective ventilation is the combination of low airway pressures and tidal volume (Vt) combined with extra corporeal carbon dioxide removal (ECCO2R). A recent large study showed no benefit of ultra-protective ventilation compared to standard ventilation in ARDS (Acute Respiratory Distress Syndrome) patients. However, the reduction in Vt failed to achieve the objective of less than or equal to 3 ml/kg predicted body weight (PBW). The main objective of our study was to assess the feasibility of the ultra-low volume ventilation (Vt ≤ 3 ml/kg PBW) facilitated by ECCO2R in acute respiratory failure patients.Methods : Retrospective analysis of a prospective cohort of patients with either high or low blood flow veno-venous ECCO2R devices. A session was defined as a treatment of ECCO2R from the start to the removal of the device (one patient could have one more than one session). Primary endpoint was the proportion of sessions during which a Vt less or equal to 3 ml/kg PBW at 24h after the start of ECCO2R was successfully achieved for at least 12 h. Secondary endpoints were respiratory variables, rate of adverse events and outcomes.Results : Forty-five ECCO2R sessions were recorded among 41 patients. Ultra-low volume ventilation (tidal volume ≤ 3 ml/kg PBW, success group) was successfully achieved at 24 h in 40.0% sessions (18 out of 45 sessions, confidence interval 25.3-54.6%). At 24 h, tidal volume in the failure group was 4.1 [3.8-4.5] ml/kg PBW compared to 2.1 [1.9-2.5] in the success group (p < 0.001). After multivariate analysis, blood flow rate was significantly associated with success of ultra-low volume ventilation (adjusted OR per 100 ml/min increase 1.51 (95%CI 1.21-1.90, p = 0.0003).Conclusion : Ultra-low volume ventilation (≤ 3 ml/kg PBW) was feasible in 18 out of 45 sessions. Higher blood flow rates were associated with the success of ultra-low volume ventilation.

Suggestions

Du même auteur

Outcomes and time trends of acute respiratory distress syndrome patients with and without liver cirrhosis: an observational cohort

Archive ouverte | Pensier, Joris | CCSD

International audience. Background In studies prior to lung-protective ventilation, liver cirrhosis in acute respiratory distress syndrome (ARDS) was associated with high mortality rates. Since patients with cirrhos...

Incidence, risk factors and long-term outcomes for extubation failure in intensive care unit in patients with obesity A retrospective analysis of a multicenter prospective observational study.

Archive ouverte | de Jong, Audrey | CCSD

International audience. BACKGROUND: To our knowledge, no large observational study has compared the incidence and risk factors for extubation failure within 48 h and during ICU stay in the same cohort of unselected ...

Noninvasive respiratory support following extubation in critically ill adults with obesity: a systematic review and network meta-analysis

Archive ouverte | Pensier, Joris | CCSD

International audience. Background : Patients with obesity are at high-risk of extubation failure. Discrepancies were found in the results of recent randomized controlled trials (RCTs) regarding the roles of noninva...

Chargement des enrichissements...