Exploring strategies to rapidly identify false positives in high-sensitivity cardiac troponin I assay: A prospective study

Archive ouverte

Desaegher, Anthony | Marin, Victor | Beauvieux, Marie-Christine | Colombiès, Brigitte | Lauga, Margaux | Alloug, Sonia | Kalkan, Selen | Castaing-Mouhica, Gladys | Lacape, Geneviève | Rucheton, Benoit | Doublet, Julien | Dabernat, Sandrine | Bats, Marie-Lise

Edité par CCSD ; Elsevier -

International audience. Abstract The evaluation of the efficacy of a drug is a fundamental step in the development of new treatments or in personalized therapeutic strategies and patient management. Ideally, this evaluation should be rapid, possibly in real time, easy to perform and reliable. In addition, it should be associated with as few adverse effects as possible for the patient. In this study, we present a device designed to meet these goals for assessing therapeutic response. This theranostic device is based on the use of magnetic resonance imaging and spectroscopy for the diagnostic aspect and on the application of the convection-enhanced delivery technique for the therapeutic aspect. The miniaturized device is implantable and can be used in vivo in a target tissue. In this study, the device was applied to rodent glioma models with local administration of choline kinase inhibitor and acquisition of magnetic resonance images and spectra at 7 Tesla. The variations in the concentration of key metabolites measured by the device during the administration of the molecules demonstrate the relevance of the approach and the potential of the device.

Consulter en ligne

Suggestions

Du même auteur

Impact of Albumin Assays in the Diagnosis of Malnutrition in Hemodialysis Patients: A Cohort Study.

Archive ouverte | Rami Arab, Lila | CCSD

International audience. In hemodialysis (HD) patients, malnutrition should be diagnosed by several assessment tools including a plasma albumin concentration of less than 3.8 g/dL or 3.5 g/dL using bromocresol green ...

Covichem: A biochemical severity risk score of COVID-19 upon hospital admission

Archive ouverte | Bats, Marie-Lise | CCSD

International audience. Clinical and laboratory predictors of COVID-19 severity are now well described and combined to propose mortality or severity scores. However, they all necessitate saturable equipment such as ...

Pigments test strips: A rapid companion test to exclude sub-arachnoid haemorrhage

Archive ouverte | Boutin, Julian | CCSD

International audience. OBJECTIVES: Subarachnoid haemorrhage (SAH) is characterised by 25% of mortality or induces long-term care. It needs immediate diagnosis with computed tomography (CT) scan. For the inconclusiv...

Chargement des enrichissements...