Cardiovascular effects on high-resolution 3D multi-shot diffusion MRI of the rhesus macaque brain

Archive ouverte

Bihan-Poudec, Yann | Tounekti, Slimane | Troalen, Thomas | Rayson, Holly | Froesel, Mathilda | Lamberton, Franck | Zariry, Zakaria | Gacoin, Maëva | Richard, Nathalie | Hamed, Suliann, Ben | Hiba, Bassem

Edité par CCSD ; MIT Press -

International audience.

The monkey brain represents a key research model thanks to its strong homologies with the humans, but diffusion-MRI (dMRI) performed at millimeter-level resolution using clinical scanners and pulse-sequences cannot take full advantage of this. Cardiovascular effects on 3D multi-shot Echo-Planar Imaging (3D-msEPI) dMRI were characterized at submillimetric resolution by comparing triggered and non-triggered diffusion-weighted (DW)-images and diffusion tensor imaging (DTI) maps. We also investigated the value of 3D-msEPI with cardiovascular-triggering to achieve dMRI of the anesthetized macaque brain with high resolution previously restricted to ex-vivo brains. Eight DW-images with voxel-size = 0.5 × 0.5 × 1 mm 3 and b = 1500 s/mm 2 were collected at 3 Tesla from two macaques using triggered and then non-triggered 3D-msEPI. Statistical analysis by mixed models was used to compare signal-to-noise ratio (SNR) and ghost-to-signal ratio (GSR) of DW-images with and without triggering. Brain DTI with isotropic-resolution of 0.4 mm and b = 1000 s/mm 2 was also collected in three macaques with triggered 3D-msEPI and reapplied without triggering in one. Cardiovascular pulsations induce inter-shot phase-errors with non-linear spatial dependency on DW-images, resulting in ghost-artifacts and signal loss particularly in the brainstem, thalamus, and cerebellum. Cardiovascular-triggering proved effective in addressing these, recovering SNR in white and gray matter (all p < 0.0001), and reducing GSR from 16.5 ± 10% to 4.7 ± 4.2% on DW-images (p < 0.0001). Triggered 3D-msEPI provided DTI-maps with the unprecedented spatial-resolution of 0.4 mm, enabling several substructures of the macaque brain to be discerned and thus analyzed in vivo. The value of cardiovascular-triggering in maintaining DTI-map sharpness and guaranteeing accurate tractography results in the brainstem, thalamus, and cerebellum was also demonstrated. In conclusion, this work highlights the effects of cardiovascular pulsations on brain 3D-dMRI and the value of triggered 3D-msEPI to provide high-quality diffusion-MRI of the anesthetized macaque brain. For routine studies, 3D-msEPI must be coupled with appropriate techniques to reduce acquisition duration.

Suggestions

Du même auteur

Cardiovascular Effects on High Resolution 3D Multi-Shot Diffusion MRI of the Rhesus Macaque Brain: Cardiovascular effects on 3D-dMRI of the Macaque Brain

Archive ouverte | Bihan-Poudec, Yann | CCSD

International audience. Abstract The monkey brain represents a key research model thanks to its strong homologies with the humans, but diffusion-MRI (dMRI) performed at millimeter-level resolution using clinical sca...

High-resolution 3D diffusion tensor MRI of anesthetized rhesus macaque brain at 3T

Archive ouverte | Tounekti, Slimane | CCSD

International audience. Diffusion Magnetic Resonance Imaging (dMRI) has been widely used to investigate human brain microstructure and connectivity and its abnormalities in a variety of brain deficits, whether acute...

Evaluation of markerless prospective motion correction for neuroanatomical MRI

Archive ouverte | Zariry, Zakaria | CCSD

International audience. Head-motion is a main cause of artifacts in MRI. The performance of a markerless optical system, which records the subject's face, estimates head-motion, and allows real-time repositioning of...

Chargement des enrichissements...