Monitoring of ionized magnesium in hemodialysis patients: A useful tool to allow a personalized prescription of dialysate composition

Archive ouverte

Bargnoux, Anne-Sophie | Morena, Marion | Rodriguez, Annie | Courtais-Coulon, Caroline | Dupuy, Anne-Marie | Kuster, Nils | Chalabi, Lotfi | Cristol, Jean-Paul

Edité par CCSD ; Elsevier -

International audience. Background and aims: The dialysate magnesium (Mg) concentration is a major determinant of Mg balance in hemodialysis. This study aimed to assess the systemic variations of total (tMg) and ionized Mg (iMg) during a dialysis session using acetate or citrate fluids and 0.5 or 0.75 mM Mg.Materials and methods: 134 patients in maintenance hemodialysis were assigned to a dialysis session with 4 different dialysates: acetate fluid with 0.5 mM Mg (1) or 0.75 mM Mg (2), citrate fluid with 0.5 mM Mg (3) or 0.75 mM Mg (4). Ionized form was measured by direct ion-selective electrode.Results: A Mg loss was observed in both acetate (0.12 and 0.08 mmol/L) and citrate (0.13 and 0.14 mmol/L for tMg and iMg, respectively) fluid groups containing 0.5 mM Mg. The use of acetate and citrate dialysates with 0.75 mM Mg led to a significant median intra-dialytic increase of 0.15 and 0.08 mmol/L for tMg, respectively. A significant augmentation in iMg concentration with acetate (0.11 mmol/L) but not with citrate dialysate (0.02 mmol/L) was observed.Conclusion: While a dialysate Mg concentration at 0.5 mM leads to a negative balance, increasing the concentration to 0.75 mM significantly raises post-dialysis circulating Mg. Monitoring of iMg should allow a personalized prescription in dialysate Mg.

Suggestions

Du même auteur

Evaluation of a new point-of-care testing for creatinine and urea measurement

Archive ouverte | Bargnoux, Anne-Sophie | CCSD

International audience. Point of care testing makes it possible to obtain results in an extremely short time. Recently, radiometer has expanded the panel of tests available on its ABL90 FLEX PLUS blood gas analyzer ...

Randomised trial on clinical performances and biocompatibility of four high-flux hemodialyzers in two mode treatments: hemodialysis vs post dilution hemodiafiltration

Archive ouverte | Morena, Marion | CCSD

International audience. This prospective multicenter randomized comparative cross-over trial aimed at evaluating the influence of hemodialysis vs post-dilution hemodiafiltration with high-flux dialyzers in solute cl...

How to interpret cardiac biomarkers in renal failure and elderly?

Archive ouverte | Bargnoux, Anne-Sophie | CCSD

International audience

Chargement des enrichissements...