Intra‐ and interlaboratory reproducibility evaluation toward international validation status of the AmpFire assay

Archive ouverte

Chung, Pui Yan Jenny | Dhillon, Sharonjit | Baraquin, Alice | Tkachenka, Yuliya | Jacquot, Killian | Prétet, Jean‐luc | Broeck, Davy Vanden | Arbyn, Marc

Edité par CCSD ; Wiley-Blackwell -

International audience. Abstract To meet the screening goal of WHO's 90‐70‐90 strategy aimed at eliminating cervical cancer (CC) by 2030, clinical validation of human papillomavirus (HPV) assays is essential to provide accurate and valid results through fulfilling three criteria of the international validation guidelines (IVGs). Previously, the clinical accuracy of the AmpFire® HPV Screening 16/18/HR assay (AmpFire assay) was reported but reproducibility data are lacking. Here, we aim to evaluate the intra‐ and inter‐laboratory reproducibility of the AmpFire assay. The reproducibility of the isothermal AmpFire assay was assessed using 556 cervical cell samples collected from women attending CC screening and biobanked in a Belgian HPV national reference center. This assay detects HPV16, HPV18, and 12 other high‐risk HPV (hrHPV) types (31/33/35/39/45/51/52/56/58/59/66/68) in aggregate. Lower 95% confidence interval bound around the assay's reproducibility should exceed 87%, with κ ≥ 0.50. Additionally, a literature review of the assay's clinical performance was performed. The AmpFire assay showed an excellent intralaboratory (96.4%, 95% CI:94.5–97.8%, κ = 0.920) and interlaboratory (95.3%, 95% CI:93.2–96.9%, κ = 0.897) reproducibility. One study demonstrated noninferior sensitivity of a prototype AmpFire assay targeting 15 hrHPV types (including HPV53) to detect CIN2+. However, clinical specificity became similar to the comparator after removing HPV53 from analyses. The low‐cost and easy‐to‐use AmpFire assay presents excellent reproducibility and—after removing HPV53 from the targeted types—fulfills also clinical accuracy requirements. Inclusion of HPV53, which is not recognized as carcinogenic, comprises clinical specificity of screening assays.

Consulter en ligne

Suggestions

Du même auteur

The Sansure® Human Papillomavirus DNA Diagnostic Kit offers excellent reproducibility performance for the detection of high‐risk HPV

Archive ouverte | Prétet, Jean‐luc | CCSD

International audience. Abstract Cervical cancer screening is a cornerstone of cervical cancer elimination. Detection of high‐risk human papillomavirus (hrHPV) is recommended as the first step in screening provided ...

Criteria for second generation comparator tests in validation of novel HPV DNA tests for use in cervical cancer screening

Archive ouverte | Arbyn, Marc | CCSD

International audience. Abstract While HC2 and GP5+/6+ PCR‐EIA were pivotal in test validation of new HPV assays, they represent the first generation of comparator tests based upon technologies that are not in wides...

Human papillomavirus negative high grade cervical lesions and cancers: Suggested guidance for HPV testing quality assurance

Archive ouverte | Prétet, Jean Luc | CCSD

International audience

Chargement des enrichissements...