Tri-axial rubidium and helium optically pumped magnetometers for on-scalp magnetoencephalography recording of interictal epileptiform discharges: a case study

Archive ouverte

Feys, Odile | Corvilain, Pierre | Labyt, Etienne | Mahmoudzadeh, Mahdi | Routier, Laura | Sculier, Claudine | Holmes, Niall | Brookes, Matthew | Goldman, Serge | Romain, Rudy | Mitryukovskiy, Sergey | Palacios-Laloy, Agustin | Schwartz, Denis | Betrouni, Nacim | Derambure, Philippe | Wallois, Fabrice | Wens, Vincent | de Tiège, Xavier

Edité par CCSD ; Frontiers -

International audience. Cryogenic magnetoencephalography (MEG) enhances the presurgical assessment of refractory focal epilepsy (RFE). Optically pumped magnetometers (OPMs) are cryogen-free sensors that enable on-scalp MEG recordings. Here, we investigate the application of tri-axial OPMs [ 87 Rb (Rb-OPM) and 4 He gas (He-OPM)] for the detection of interictal epileptiform discharges (IEDs). IEDs were recorded simultaneously with 4 tri-axial Rb- and 4 tri-axial He-OPMs in a child with RFE. IEDs were identified visually, isolated from magnetic background noise using independent component analysis (ICA) and were studied following their optimal magnetic field orientation thanks to virtual sensors. Most IEDs (>1,000) were detectable by both He- and Rb-OPM recordings. IEDs were isolated by ICA and the resulting magnetic field oriented mostly tangential to the scalp in Rb-OPMs and radial in He-OPMs. Likely due to differences in sensor locations, the IED amplitude was higher with Rb-OPMs. This case study shows comparable ability of Rb-OPMs and He-OPMs to detect IEDs and the substantial benefits of triaxial OPMs to detect IEDs from different sensor locations. Tri-axial OPMs allow to maximize spatial brain sampling for IEDs detection with a limited number of sensors.

Consulter en ligne

Suggestions

Du même auteur

Performance Analysis of Optically Pumped He-4 Magnetometers vs. Conventional SQUIDs: From Adult to Infant Head Models

Archive ouverte | Zahran, Saeed | CCSD

International audience. Optically pumped magnetometers (OPMs) are new, room-temperature alternatives to superconducting quantum interference devices (SQUIDs) for measuring the brain's magnetic fields. The most used ...

A New Generation of OPM for High Dynamic and Large Bandwidth MEG: The 4He OPMs—First Applications in Healthy Volunteers

Archive ouverte | Gutteling, Tjerk | CCSD

International audience. MagnetoEncephaloGraphy (MEG) provides a measure of electrical activity in the brain at a millisecond time scale. From these signals, one can non-invasively derive the dynamics of brain activi...

Helium optically pumped magnetometers can detect epileptic abnormalities as well as squids as shown by intracerebral recordings

Archive ouverte | Badier, Jean-Michel | CCSD

International audience. Magnetoencephalography based on superconducting quantum interference devices (SQUIDs) has been shown to improve the diagnosis and surgical treatment decision for presurgical evaluation of dru...

Chargement des enrichissements...