Integration of operator-validated contours in deformable image registration for dose accumulation in radiotherapy

Archive ouverte

Bosma, Lando | Ries, Mario | Denis de Senneville, Baudouin | Raaymakers, Bas | Zachiu, Cornel

Edité par CCSD ; ESTRO, the European SocieTy for Radiotherapy & Oncology, -

International audience. Background and purpose. Deformable image registration (DIR) is a core element of adaptive radiotherapy workflows, integrating daily contour propagation and/or dose accumulation in their design. Propagated contours are usually manually validated and may be edited, thereby locally invalidating the registration result. This means the registration cannot be used for dose accumulation. We present and validated a novel multi-modal DIR algorithm that incorporates contour information to guide the registration. This ensures that the estimated deformation vector field and warped dose are in accordance with operator-validated contours.Materials and methods. The proposed algorithm minimizes both a normalized gradient field-based data-fidelity term on the images and an optical flow data-fidelity term on the contours. The Helmholtz-Hodge decomposition was incorporated to ensure anatomically plausible deformations. The algorithm was validated for same-and cross-contrast Magnetic Resonance (MR) image registrations, Computed Tomography (CT) registrations, and CT-to-MR registrations for different anatomies, all based on challenging clinical situations. The contour-correspondence, anatomical fidelity, registration error, and dose warping error were evaluated.Results. The proposed contour-guided algorithm considerably and significantly increased contour overlap, decreasing the mean distance to agreement by a factor of 1.3 to 13.7, compared to the best algorithm without contour-guidance. Importantly, the registration error and dose warping error decreased significantly, by a factor of 1.2 to 2.0.Conclusion. Our contour-guided algorithm ensures that the deformation vector field and warped quantitative information are consistent with the operator-validated warped contours. This presents a feasible semi-automatic strategy for spatially correct warping of quantitative information even in difficult and artefacted cases.

Suggestions

Du même auteur

Technical Note: Intensity-based quality assurance criteria for deformable image registration in image-guided radiotherapy

Archive ouverte | Bosma, Lando | CCSD

International audience. Background: Deformable image registration is increasingly used in radiotherapy to adapt the treatment plan and accumulate the delivered dose. Consequently, clinical workflows using deformable...

An Adaptive Non-Local-Means Filter for Real-Time MR-Thermometry

Archive ouverte | Zachiu, Cornel | CCSD

International audience. Proton resonance frequency shift-based magnetic resonance thermometry is a currently used technique for monitoring temperature during targeted thermal therapies. However, in order to provide ...

A framework for continuous target tracking during MR-guided high intensity focused ultrasound thermal ablations in the abdomen

Archive ouverte | Zachiu, Cornel | CCSD

International audience. Background: During lengthy magnetic resonance-guided high intensity focused ultrasound (MRg-HIFU) thermal ablations in abdominal organs, the therapeutic work-flow is frequently hampered by va...

Chargement des enrichissements...