How and when to measure pH in IVF culture media: validation of a portable blood gas analyzer in two IVF culture dishes for time lapse and conventional incubators

Archive ouverte

Chansel-Debordeaux, Lucie | Carles, Manon | Moreau, Jessika | Depuydt, Chloé | Gallo, Sylvie | Genvrin, Edwige | Léandri, Roger | Gatimel, Nicolas

Edité par CCSD ; Springer Verlag -

International audience. Purpose :Maintaining a stable pH at optimal level in human embryo culture media is crucial for embryo development but poses a challenge for all IVF laboratories. We validate analytically reliable conditions for pH measurement that are as close as possible to the embryo microenvironment during IVF.MethodsThis was a multicentric study. A Siemens EPOC portable blood gas analyzer was used. The analytical validation was carried out under the culture medium (Global Total HSA (R)) conditions of use (microdroplets, under oil overlay, in a IVF incubator with (EmbryoScope (R)) or without a time lapse system (K system G210+(R)) and using IVF dishes. The validation included repeatability ("within-run" precision), total precision (between-day precision), trueness based on inter-laboratory comparison, inaccuracy based on external quality assessment and comparison to the reference technique. We also assessed the pre-analytical medium incubation time required to obtain a target value.ResultsA measurement after an incubation period of 24 to 48 h is more representative of the pH to which the embryo will be exposed throughout the culture. The "within-run" and "between-day" precision show very low coefficients of variation (CV%): 0.17 to 0.22% and 0.13 to 0.34%, respectively, with IVF culture media. Trueness (% bias) range from - 0.07 to - 0.03%. We demonstrate good correlation between EPOC and reference pH electrode with an overestimation of 0.03 pH units of EPOC.ConclusionOur method demonstrates good analytical performance for IVF laboratories wishing to implement a robust quality assurance system to monitor pH in embryo culture media. Compliance with stringent pre-analytical and analytical conditions is essential.

Consulter en ligne

Suggestions

Du même auteur

Is in vitro maturation of oocytes retrieved ex vivo from ovarian tissue an effective fertility preservation technique in the presence of organic ovarian cysts?

Archive ouverte | Bourg, Mona | CCSD

International audience. Objective(s): In vitro maturation (IVM) of oocytes retrieved ex vivo from ovarian tissue (OTO-IVM) could be an additional source of mature oocytes with the potential to optimise medical ferti...

Involvement of CATSPER 2 mutation in a familial context of unexplained infertility and fertilization failure associated with hearing loss: a case report

Archive ouverte | Guignard, Simon | CCSD

International audience. Objective - To explore the functional implications of a homozygous (cation channel for sperm) deletion within the acrosome reaction pathway during fertilization in 2 brothers, who have unexp...

Semi-automated versus manual embryo vitrification: inter-operator variability, time-saving, and clinical outcomes

Archive ouverte | Gatimel, Nicolas | CCSD

International audience. Purpose: Does semi-automated vitrification have lower inter-operator variability and better clinical outcomes than manual vitrification?Methods: Retrospective analyses of 282 patients whose e...

Chargement des enrichissements...