Microbiological Contamination of the Office Environment in Dental and Medical Practice

Archive ouverte

Baudet, Alexandre | Guillaso, Monique | Grimmer, Léonie | Regad, Marie | Florentin, Arnaud

Edité par CCSD ; MDPI -

International audience. The microbiological contamination of the environment in independent healthcare facilities such as dental and general practitioner offices was poorly studied. The aims of this study were to describe qualitatively and quantitatively the bacterial and fungal contamination in these healthcare facilities and to analyze the antibiotic resistance of bacterial pathogens identified. Microbiological samples were taken from the surfaces of waiting, consulting, and sterilization rooms and from the air of waiting room of ten dental and general practitioner offices. Six surface samples were collected in each sampled room using agar contact plates and swabs. Indoor air samples were collected in waiting rooms using a single-stage impactor. Bacteria and fungi were cultured, then counted and identified. Antibiograms were performed to test the antibiotic susceptibility of bacterial pathogens. On the surfaces, median concentrations of bacteria and fungi were 126 (range: 0–1280) and 26 (range: 0–188) CFU/100 cm2, respectively. In indoor air, those concentrations were 403 (range: 118–732) and 327 (range: 32–806) CFU/m3, respectively. The main micro-organisms identified were Gram-positive cocci and filamentous fungi, including six ubiquitous genera: Micrococcus, Staphylococcus, Cladosporium, Penicillium, Aspergillus, and Alternaria. Some antibiotic-resistant bacteria were identified in general practitioner offices (penicillin- and erythromycin-resistant Staphylococcus aureus), but none in dental offices. The dental and general practitioner offices present a poor microbiological contamination with rare pathogenic micro-organisms.

Suggestions

Du même auteur

La qualité de l’air intérieur des structures médico-sociales et libérales

Archive ouverte | Baurès, Estelle | CCSD

National audience. La qualité de l’air intérieur est à ce jour encore peu étudiée. Via le projet MEDIQAI, deux campagnes de prélèvements et mesures (été 2018 et hiver 2019) ont été menées à Rennes et Nancy, dans six...

Indoor Air Quality in Healthcare and Care Facilities: Chemical Pollutants and Microbiological Contaminants

Archive ouverte | Baudet, Alexandre | CCSD

International audience. The indoor air quality of healthcare and care facilities is poorly studied. The aim of this study was to qualitatively and quantitatively describe the chemical pollution and the microbiologic...

An unprecedented and large-scale support mission to assist residential care facilities during the COVID-19 pandemic

Archive ouverte | Colas, Anaïs | CCSD

International audience

Chargement des enrichissements...