Development and validation of a multivariable prediction model of central venous catheter-tip colonization in a cohort of five randomized trials

Archive ouverte

Iachkine, Jeanne | Buetti, Niccolò | de Grooth, Harm-Jan | Briant, Anaïs | Mimoz, Olivier | Mégarbane, Bruno | Mira, Jean-Paul | Ruckly, Stéphane | Souweine, Bertrand | Du Cheyron, Damien | Mermel, Leonard | Timsit, Jean-François | Parienti, Jean-Jacques

Edité par CCSD ; BioMed Central -

International audience. Abstract Background The majority of central venous catheters (CVC) removed in the ICU are not colonized, including when a catheter-related infection (CRI) is suspected. We developed and validated a predictive score to reduce unnecessary CVC removal. Methods We conducted a retrospective cohort study from five multicenter randomized controlled trials with systematic catheter-tip culture of consecutive CVCs. Colonization was defined as growth of ≥10 3 colony-forming units per mL. Risk factors for colonization were identified in the training cohort (CATHEDIA and 3SITES trials; 3899 CVCs of which 575 (15%) were colonized) through multivariable analyses. After internal validation in 500 bootstrapped samples, the CVC-OUT score was computed by attaching points to the robust (> 50% of the bootstraps) risk factors. External validation was performed in the testing cohort (CLEAN, DRESSING2 and ELVIS trials; 6848 CVCs, of which 588 (9%) were colonized). Results In the training cohort, obesity (1 point), diabetes (1 point), type of CVC (dialysis catheter, 1 point), anatomical insertion site (jugular, 4 points; femoral 5 points), rank of the catheter (second or subsequent, 1 point) and catheterization duration (≥ 5 days, 2 points) were significantly and independently associated with colonization . Area under the ROC curve (AUC) for the CVC-OUT score was 0.69, 95% confidence interval (CI) [0.67–0.72]. In the testing cohort, AUC for the CVC-OUT score was 0.60, 95% CI [0.58–0.62]. Among 1,469 CVCs removed for suspected CRI in the overall population, 1200 (82%) were not colonized. The negative predictive value (NPV) of a CVC-OUT score < 6 points was 94%, 95% CI [93%–95%]. Conclusion The CVC-OUT score had a moderate ability to discriminate catheter-tip colonization, but the high NPV may contribute to reduce unnecessary CVCs removal. Preference of the subclavian site is the strongest and only modifiable risk factor that reduces the likelihood of catheter-tip colonization and consequently the risk of CRI. Clinical Trials Registration : NCT00277888, NCT01479153, NCT01629550, NCT01189682, NCT00875069.

Consulter en ligne

Suggestions

Du même auteur

Development and validation of a multivariable model predicting the required catheter dwell time among mechanically ventilated critically ill patients in three randomized trials

Archive ouverte | Iachkine, Jeanne | CCSD

International audience. Background The anatomic site for central venous catheter insertion influences the risk of central venous catheter-related intravascular complications. We developed and validated a predictive ...

Ultrasound Guidance and Risk for Central Venous Catheter–Related Infections in the Intensive Care Unit: A Post Hoc Analysis of Individual Data of 3 Multicenter Randomized Trials

Archive ouverte | Buetti, Niccolò | CCSD

International audience. Abstract Background Ultrasound (US) guidance is frequently used in critically ill patients for central venous catheter (CVC) insertion. The effect of US on infectious risk remains controversi...

Ultrasound Guidance and Risk for Central Venous Catheter–Related Infections in the Intensive Care Unit: A Post Hoc Analysis of Individual Data of 3 Multicenter Randomized Trials

Archive ouverte | Buetti, Niccolò | CCSD

International audience. Abstract Background Ultrasound (US) guidance is frequently used in critically ill patients for central venous catheter (CVC) insertion. The effect of US on infectious risk remains controversi...

Chargement des enrichissements...