Airway replacement using stented aortic matrices: Long‐term follow‐up and results of the TRITON ‐01 study in 35 adult patients

Archive ouverte

Martinod, Emmanuel | Radu, Dana M. | Onorati, Ilaria | Portela, Ana Maria Santos | Peretti, Marine | Guiraudet, Patrice | Destable, Marie‐dominique | Uzunhan, Yurdagül | Freynet, Olivia | Chouahnia, Kader | Duchemann, Boris | Kabbani, Jamal | Maurer, Cyril | Brillet, Pierre‐yves | Fath, Léa | Brenet, Esteban | Debry, Christian | Buffet, Camille | Leenhardt, Laurence | Clero, Dominique | Julien, Nicolas | Vénissac, Nicolas | Tronc, François | Dutau, Hervé | Marquette, Charles‐hugo | Juvin, Charles | Lebreton, Guillaume | Cohen, Yves | Zogheib, Elie | Beloucif, Sadek | Planès, Carole | Trésallet, Christophe | Bensidhoum, Morad | Petite, Hervé | Rouard, Hélène | Miyara, Makoto | Vicaut, Eric

Edité par CCSD ; Elsevier -

Over the past 25 years, we have demonstrated the feasibility of airway bioengineering using stented aortic matrices experimentally then in a first-in-human trial (n = 13). The present TRITON-01 study analyzed all the patients who had airway replacement at our center to confirm that this innovative approach can be now used as usual care. For each patient, the following data were prospectively collected: postoperative mortality and morbidity, late airway complications, stent removal and status at last follow-up on November 2, 2021. From October 2009 to October 2021, 35 patients had airway replacement for malignant (n = 29) or benign (n = 6) lesions. The 30-day postoperative mortality and morbidity rates were 2.9% (n = 1/35) and 22.9% (n = 8/35) respectively. At a median follow-up of 29.5 months (range 1-133 months), 27 patients were alive. There have been no deaths directly related to the implanted bioprosthesis. Eighteen patients (52.9%) had stent-related granulomas requiring a bronchoscopic treatment. Ten among 35 patients (28.6%) achieved a stent free survival. The actuarial 2- and 5-year survival rates (Kaplan-Meier estimates) were respectively 88% and 75%. The TRITON-01 study confirmed that airway replacement using stented aortic matrices can be proposed as usual care at our center. Clinicaltrials.gov Identifier: NCT04263129. Keywords: airway replacement/pulmonology; clinical research/practice; surgical technique; tissue/organ engineering; translational research/science.

Consulter en ligne

Suggestions

Du même auteur

Diagnosis Yield and Safety of Surgical Biopsy in Interstitial Lung Diseases: A Prospective Study

Archive ouverte | Radu, Dana | CCSD

International audience

Elective extra corporeal membrane oxygenation for high-risk rigid bronchoscopy

Archive ouverte | Martinod, Emmanuel | CCSD

International audience. The use of extracorporeal membrane oxygenation for high-risk rigid bronchoscopy has been reported in few urgent cases. We report our experience with this approach which was planned electively...

Correction: Rare predicted loss-of-function variants of type I IFN immunity genes are associated with life-threatening COVID-19

Archive ouverte | Matuozzo, Daniela | CCSD

International audience

Chargement des enrichissements...