Adaptation of the Atellica (TM) Siemens (TM) urine benzodiazepines kit to serum matrix

Archive ouverte

Mernissi, Touria | Andre, Camille | Perin, Anais | Thezee, Chloe | Talandier, Claudie | Masmoudi, Kamel | Quinton-Bouvier, Marie-Charlotte | Bennis, Youssef | Bodeau, Sandra | Lemaire-Hurtel, Anne-Sophie

Edité par CCSD ; Elsevier -

International audience. Benzodiazepines (BZD) are responsible for many drug poisonings, treated in our hospital. At the Amiens University Hospital, benzodiazepines immunoassays are performed on 2 CH 900 Atellica (TM) analysers from Siemens (TM) according to a method called ``CH Bnz'', since 2020. As the technical documentation of the test does not include the blood matrix, the pharmacology-toxicology laboratory conducted a study in order to adapt this urine screening kit to the serum matrix, by checking the detection thresholds. The experience consisted of testing serum samples spiked with a known benzodiazepine, at various concentrations close to the positivity thresholds pre-established by Siemens (TM) in the ``CH Bnz'' data sheet; the concentrations were verified by HPLC-MS/MS. The laboratory chose to test 12 benzodiazepines, selecting the most common among those available in the laboratory. The cut-off values determined in the serum matrix are around those established for the urinary matrix for alprazolam, clonazepam, diazepam and nitrazepam. The thresholds are lower for the 8 other benzodiazepines tested (bromazepam, clobazam, flurazepam, midazolam, nordiazepam, oxazepam, prazepam and temazepam). It should also be noted that the thresholds evaluated on our site are in accordance with low or therapeutic concentrations for most of the molecules tested. This work enabled the adaptation of the documentation provided by Siemens (TM) to the serum matrix in order to maintain its accreditation in flexible standard A scope by the French Accreditation Committee (COFRAC), according to standard NF EN ISO 15189. It also took into consideration the requirements of the opposable document HS REF 08. (C) 2021 Societe Francaise de Toxicologie Analytique. Published by Elsevier Masson SAS. All rights reserved.

Suggestions

Du même auteur

Coma chez un nourrisson : les amphétaminiques en cause

Archive ouverte | Mernissi, Touria | CCSD

International audience. ObjectifsDocumenter une intoxication pédiatrique à des dérivés amphétaminiques ayant conduit à un état de mal épileptique généralisé et un coma chez un nourrisson.MéthodesAlertés par un brusq...

A new case of sodium nitrite poisoning at the Amiens-Picardie University Hospital: A growing phenomenon?. Un nouveau cas d’intoxication au nitrite de sodium au CHU Amiens-Picardie : un phénomène qui prend de l’ampleur ?

Archive ouverte | André, Camille | CCSD

International audience. Sodium nitrite is a product used by the food industry as a preservative for processed meats. Autolysis from this type of nitrite derivative is often fatal. The case presented here concerns a ...

Soumissions chimiques : état des lieux amiénois en 2022

Archive ouverte | Lemaire-Hurtel, Anne-Sophie | CCSD

International audience. ObjectifsDevant l’augmentation des demandes de prise en charge de soumissions chimiques, nous avons cherché à en déterminer les caractéristiques tant sur le plan des victimes, des agresseurs ...

Chargement des enrichissements...