Flow-Diversion Treatment for Unruptured ICA Bifurcation Aneurysms with Unfavorable Morphology for Coiling

Archive ouverte

Cagnazzo, Federico | Derraz, Imad | Dargazanli, Cyril | Lefevre, Pierre-Henri | Coelho Ferreira, Ivan | Gascou, Gregory | Riquelme, Carlos | Fanti, Andrea | Ahmed, Raed | Frandon, Julien | Bonafe, Alain | Costalat, Vincent

Edité par CCSD ; American Society of Neuroradiology -

International audience. Background and purpose: Few reports described flow diversion for ICA bifurcation aneurysms. Our aim was to provide further insight into flow diversion for ICA bifurcation aneurysms difficult to treat with other strategies.Materials and methods: Consecutive patients receiving flow diverters for unruptured ICA bifurcation aneurysms were collected. Aneurysm occlusion (O'Kelly-Marotta grading scale) and clinical outcomes were evaluated.Results: Twenty saccular ICA bifurcation aneurysms were treated with the Pipeline Embolization Device deployed from the M1 to the ICA, covering the aneurysm and the A1 segment. All patients presented with an angiographic visualized contralateral flow from the anterior communicating artery. Mean aneurysm size was 6.5 (SD, 3.2) mm (range, 4.5-20 mm). All lesions had an unfavorable dome-to-neck ratio (mean/median, 1.6/1.6; range, 0.8-2.8; interquartile range = 0.5) or aspect ratio for coiling (mean/median = 1.5/1.55; range, 0.8-2.5; interquartile range = 0.6). One was a very large aneurysm (20 mm). Nineteen medium-sized lesions were completely occluded during the angiographic follow-up (13 months). No cases of aneurysm rupture or retreatment were reported. No adverse events were described. Aneurysm occlusion was associated with the asymptomatic flow modification of the covered A1 that was occluded and contralaterally filled among 10 patients (50%), narrowed among 9 patients (45%), and unchanged in 1 subject (5%). There was no difference in the mean initial diameter of the occluded (2.1 [SD 0.4] mm; range, 1.6-3 mm) and narrowed (2 [SD, 0.2] mm; range, 1.7-2.6 mm) A1 segments.Conclusions: Medium-sized unruptured ICA bifurcation aneurysms with unfavorable morphology for coiling can be treated with M1 ICA flow diversion. Aneurysm occlusion is associated with flow modifications of the covered A1 that seems safe in the presence of a favorable collateral anatomy through the anterior communicating artery complex.

Consulter en ligne

Suggestions

Du même auteur

Distal anterior cerebral artery aneurysms treated with flow diversion: experience of a large-volume center and systematic review of the literature

Archive ouverte | Cagnazzo, Federico | CCSD

International audience. Background Evidence about the safety and the efficacy of flow diversion for distal anterior cerebral artery (DACA) aneurysms is scant. To provide further insight into flow diversion for aneur...

Flow modification on the internal carotid artery bifurcation region and A1 segment after M1-internal carotid artery flow diverter deployment

Archive ouverte | Cagnazzo, Federico | CCSD

International audience. Clinical and hemodynamic consequences of flow diverters extending from the M1 to the internal carotid artery (ICA), covering the A1 segment, have rarely been investigated. We aimed to provide...

Impact of endovascular reperfusion therapy in nonagenarians with anterior circulation large-vessel ischaemic stroke

Archive ouverte | Derraz, Imad | CCSD

International audience. Abstract Background and Purpose The benefit of endovascular thrombectomy (EVT) among nonagenarians (90 years or older) is poorly documented. We aimed to investigate the clinical and imaging f...

Chargement des enrichissements...