Cost-effectiveness of an insertable cardiac monitor to detect atrial fibrillation in patients with cryptogenic stroke

Archive ouverte

Ascoeta, Maria Soledad | Marijon, Eloi | Defaye, Pascal | Klug, Didier | Beganton, Frankie | Perier, Marie-Cécile | Gras, Daniel | Algalarrondo, Vincent | Deharo, Jean-Claude | Leclercq, Christophe | Fauchier, Laurent | Babuty, Dominique | Bordachar, Pierre | Sadoul, Nicolas | Boveda, Serge | Piot, Olivier | Diamantopoulos, Alex | Sawyer, Laura | Lip, Gregory Yh | Witte, Klaus | Reynolds, Matthew | Thijs, Vincent | Brown, Ben | Quiroz Angulo, Maria | Diener, Hans-Christoph

Edité par CCSD ; Wiley -

International audience. Background and aims Documentation of atrial fibrillation is required to initiate oral anticoagulation therapy for recurrent stroke prevention. Atrial fibrillation often goes undetected with traditional electrocardiogram monitoring techniques. We evaluated whether atrial fibrillation detection using continuous long-term monitoring with an insertable cardiac monitor is cost-effective for preventing recurrent stroke in patients with cryptogenic stroke, in comparison to the standard of care. Methods A lifetime Markov model was developed to estimate the cost-effectiveness of insertable cardiac monitors from a UK National Health Service perspective using data from the randomized CRYSTAL-AF trial and other published literature. We also conducted scenario analyses (CHADS 2 score) and probabilistic sensitivity analyses. All costs and benefits were discounted at 3.5%. Results Monitoring cryptogenic stroke patients with an insertable cardiac monitor was associated with fewer recurrent strokes and increased quality-adjusted life years compared to the standard of care (7.37 vs 7.22). Stroke-related costs were reduced in insertable cardiac monitor patients, but overall costs remained higher than the standard of care (£19,631 vs £17,045). The incremental cost-effectiveness ratio was £17,175 per quality-adjusted life years gained, compared to standard of care in the base-case scenario, which is below established quality-adjusted life years willingness-to-pay thresholds. When warfarin replaced non-vitamin-K oral anticoagulants as the main anticoagulation therapy, the incremental cost-effectiveness ratio was £13,296 per quality-adjusted life years gained. Conclusion Insertable cardiac monitors are a cost-effective diagnostic tool for the prevention of recurrent stroke in patients with cryptogenic stroke. The cost-effectiveness results have relevance for the UK and across value-based healthcare systems that assess costs relative to outcomes.

Consulter en ligne

Suggestions

Du même auteur

Impact of early complications on outcomes in patients with implantable cardioverter-defibrillator for primary prevention

Archive ouverte | Ascoeta, Maria Soledad | CCSD

International audience. Background - The lifesaving benefit of implantable cardioverter-defibrillators (ICDs) has been demonstrated. Their use has increased considerably in the past decade, but related complications...

Implantable cardioverter defibrillator therapy for primary prevention of sudden cardiac death in the real world: Main findings from the French multicentre DAI-PP programme (pilot phase). Implantation des défibrillateurs en prévention primaire dans la vraie vie: les principaux résultats de la phase pilote du programme DAIPP

Archive ouverte | Boveda, Serge | CCSD

International audience. This review summarizes the main findings of the French multicentre DAI-PP pilot programme, and discusses the related clinical and research perspectives. This project included retrospectively ...

Dual- vs. single-chamber defibrillators for primary prevention of sudden cardiac death: long-term follow-up of the Défibrillateur Automatique Implantable—Prévention Primaire registry

Archive ouverte | Defaye, Pascal | CCSD

International audience. AIMS: Implantable cardioverter defibrillators (ICDs) are an effective primary prevention of sudden cardiac death. We examined whether dual-chamber (DC) ICDs confer a greater benefit than sing...

Chargement des enrichissements...