Serum Pepsinogens Combined with New Biomarkers Testing Using Chemiluminescent Enzyme Immunoassay for Non-Invasive Diagnosis of Atrophic Gastritis: A Prospective, Multicenter Study

Archive ouverte

Chapelle, Nicolas | Osmola, Malgorzata | Martin, Jérôme | Blin, Justine | Leroy, Maxime | Jirka, Iva | Moussata, Driffa | Lamarque, Dominique | Olivier, Raphaël | Tougeron, David | Hay-Lombardie, Anne | Bigot-Corbel, Edith | Masson, Damien | Mosnier, Jean-François | Matysiak-Budnik, Tamara

Edité par CCSD ; MDPI -

International audience. Background: Analysis of serum biomarkers for the assessment of atrophic gastritis (AG), a gastric precancerous lesion, is of growing interest for identification of patients at increased risk of gastric cancer. The aim was to analyze the diagnostic performance of serum pepsinogen testing using another method, chemiluminescent enzyme immunoassay (CLEIA), as well as of other new potential biomarkers.Material and Methods: The sera of patients considered at increased risk of gastric cancer and undergoing upper endoscopy collected in our previous prospective, multicenter study were tested for pepsinogen I (PGI) and II (PGII), interleukin-6 (IL-6), human epididymal protein 4 (HE-4), adiponectin, ferritin and Krebs von den Lungen (KL-6) using the CLEIA. The diagnostic performance for the detection of AG was calculated by taking histology as the reference.Results: In total, 356 patients (162 men (46%); mean age 58.6 (±14.2) years), including 152 with AG, were included. For the detection of moderate to severe corpus AG, sensitivity and specificity of the pepsinogen I/II ratio were of 75.0% (95%CI 57.8–87.9) and 92.6% (88.2–95.8), respectively. For the detection of moderate to severe antrum AG, sensitivity of IL-6 was of 72.2% (95%CI 46.5–90.3). Combination of pepsinogen I/II ratio or HE-4 showed a sensitivity of 85.2% (95%CI 72.9–93.4) for the detection of moderate to severe AG at any location.Conclusion: This study shows that PG testing by CLEIA represents an accurate assay for the detection of corpus AG. Additionally, IL-6 and HE-4 may be of interest for the detection of antrum AG.Mini-abstract: Pepsinogens testing by chemiluminescent enzyme immunoassay is accurate for the detection of corpus atrophic gastritis. IL-6 and HE-4 maybe of interest for the detection of antrum atrophic gastritis.

Suggestions

Du même auteur

Serum pepsinogens can help to discriminate between H. pylori-induced and auto-immune atrophic gastritis: Results from a prospective multicenter study

Archive ouverte | Chapelle, Nicolas | CCSD

International audience. Background: Serum pepsinogen (PG) testing is recommended by the European guidelines for diagnosis of chronic atrophic gastritis (CAG). However, wide variations in diagnostic performances are ...

Iron and Vitamin B12 Deficiency in Patients with Autoimmune Gastritis and Helicobacter pylori Gastritis: Results from a Prospective Multicenter Study

Archive ouverte | Osmola, Malgorzata | CCSD

International audience. Introduction : Iron and vitamin B12 deficiencies are common in patients with atrophic gastritis, but there are limited data on the prevalence of these deficiencies in different types of atrop...

A panel of stomach-specific biomarkers (GastroPanel®) for the diagnosis of atrophic gastritis: A prospective, multicenter study in a low gastric cancer incidence area

Archive ouverte | Chapelle, Nicolas | CCSD

International audience. Background: Analysis of serum biomarkers for the assessment of atrophic gastritis (AG), considered as gastric precancerous lesion, is of growing interest and recommended by current guidelines...

Chargement des enrichissements...