International audience. This work aims at studying the optimization of an on-line capillary electrophoresis (CE)-based tryptic digestion methodology for the analysis of therapeutic polypeptides (PP). With this methodology, a mixture of surrogate peptide fragments and amino acid were produced on-line by trypsin cleavage (enzymatic digestion) and subsequently analyzed using the same capillary. The resulting automation of all steps such as injection, mixing, incubation, separation and detection minimizes the possible errors and saves experimental time. In this paper, we first study the differents parameters influencing PP cleavage inside the capillary (plug length, reactant concentration, incubation time, diffusion and electrophoretic plugs mixing). In a second part, the optimization of the electrophoretic separation conditions of generated hydrolysis products (nature, pH and ionic strength (I) of the background electrolyte (BGE)) is described. Using the optimized conditions, excellent repeatability was obtained in terms of separation (migration times) and proteolysis (number of products from enzymatic hydrolysis and corresponding amounts) demonstrating the robustness of the proposed methodology.

Consulter en ligne

Suggestions

Du même auteur

Evaluation of capillary zone electrophoresis for the quality control of complex biologic samples: Application to snake venoms

Archive ouverte | Kpaibe, André P.S. | CCSD

International audience. Snake venoms constitute a very promising resource for the development of new medicines. They are mainly composed of very complex peptide and protein mixtures, which composition may vary signi...

Separation of 3'-azido-2',3'-dideoxythymidine pronucleotide diastereoisomers in biological samples by CZE with cyclodextrin addition.

Archive ouverte | Perrin, Catherine | CCSD

Integrated microreactor for enzymatic reaction automation: An easy step toward the quality control of monoclonal antibodies

Archive ouverte | Ladner, Yoann | CCSD

International audience. The main purpose of the present work is to provide a fully integrated miniaturized electrophoretic methodology in order to facilitate the quality control of monoclonal antibodies (mAbs). This...

Chargement des enrichissements...