Reduction of clinically important low glucose excursions with a long‐term implantable continuous glucose monitoring ( CGM ) system in adults with type 1 diabetes prone to hypoglycemia. France Adoption randomized clinical trial

Archive ouverte

Renard, Eric | Riveline, Jean‐pierre | Hanaire, Hélène | Guerci, Bruno | Clavel, Sylvaine | Sérusclat, Pierre | Bekka, Saïd | Chaillous, Lucy | Reznik, Yves | Benhamou, Pierre‐yves | Schaepelynck‐belicar, Pauline | Sola, Agnès | Fendri, Salha | Jeandidier, Nathalie | Thivolet, Charles | Cosma, Valéria

Edité par CCSD ; Wiley -

International audience. Aim: This trial assessed the outcomes on glucose control of the implantable Eversense real-time continuous glucose monitoring (CGM) system compared to self-monitoring of blood glucose or intermittently scanned CGM in patients with type 1 or type 2 diabetes (T1D or T2D).Patients and methods: This was a randomized (2:1), prospective, national, multicenter study. All participants, aged >18, on multiple daily insulin injections or insulin pump had a sensor inserted, activated only in the enabled group. Included patients had T1D or T2D with an HbA1c level >8% (cohort 1) or T1D with a time below range <70 mg/dL (TBR<70 ) >1.5 hour/day during the previous 28 days (cohort 2). The primary outcomes were the HbA1c change at D180 (cohort 1) or the change in TBR<54 during the period D90-D120 (cohort 2). A covariance model (ANCOVA) was used for endpoint analyses.Results: Overall, 149 patients were included in cohort 1 and 90 in cohort 2. In cohort 1, the adjusted mean [95%CI] difference (enabled-control) in HbA1c at D180 was -0.1% [-0.4; 0.1], p=0.341. No significant difference in time in range (TIR70-180 ) or time above range (TAR>180 ) was observed. In cohort 2, the mean adjusted difference in TBR<54 was -1.6% [-3.1; -0.1], p=0.039 during D90-D120 and remained at -2.6%, [-4.5; -0.6], p=0.011 during D150-D180 (pre-specified secondary outcome). There was no safety issue.Conclusion: This study shows that the Eversense CGM system can significantly decrease TBR<54 in patients with T1D prone to hypoglycemia.

Consulter en ligne

Suggestions

Du même auteur

No more hypoglycaemia on days with physical activity and unrestricted diet when using a closed‐loop system for 12 weeks: A post‐hoc secondary analysis of the multicentre randomized controlled Diabeloop WP7 trial

Archive ouverte | Franc, Sylvia | CCSD

International audience. Objective: To investigate the efficacy of the Diabeloop Generation-1 (DBLG1) closed-loop system to control the hypoglycaemia induced by physical activity (PA) in real-life conditions.Methods:...

Efficacy of Diabeloop closed‐loop to improve glycaemic control in patients with type 1 diabetes exposed to copious dinners or to sustained physical exercise

Archive ouverte | Hanaire, Hélène | CCSD

International audience. Aims: To compare closed-loop (CL) and open-loop (OL) systems for glycaemic control in patients with type 1 diabetes (T1D) exposed to real-life challenging situations (gastronomic dinners or s...

Closed-loop insulin delivery in adults with type 1 diabetes in real-life conditions: a 12-week multicentre, open-label randomised controlled crossover trial

Archive ouverte | Benhamou, Pierre-Yves | CCSD

International audience. Background: Closed-loop insulin delivery systems are expected to become a standard treatment for patients with type 1 diabetes. We aimed to assess whether the Diabeloop Generation 1 (DBLG1) h...

Chargement des enrichissements...