PreserFlo MicroShunt® exposure: a case series

Archive ouverte

Bunod, Roxane | Robin, Mathieu | Buffault, Juliette | Keilani, Chafik | Labbé, Antoine | Baudouin, Christophe

Edité par CCSD ; BioMed Central -

International audience. BackgroundPreserFlo® MicroShunt (PM) (also known as InnFocus® MicroShunt) is a subconjunctival stent implanted ab externo via a minimally invasive surgical procedure. The current indication is progressive, mild to moderate, open angle glaucoma uncontrolled on topical medications. According to the literature, adverse events are rare, mild and transient.Case presentationTwo cases of stand-alone PreserFlo MicroShunt® implantation in patients with uncontrolled open-angle glaucoma are reported. Exposure occurred 7 days and 3 months respectively after implantation. These cases shared common features including preexisting blepharitis and the lack of a Tenon’s flap. In both cases, removal of the device was required after several attempts at repair.ConclusionsPreserFlo MicroShunt® exposure is a potentially vision-threatening complication because of the risk of endophthalmitis. Potential risk factors include the absence of a Tenon’s flap and pre-existing ocular surface inflammation. Ocular surface inflammation should be detected and treated prior to PM implantation. If a deficiency in Tenon’s capsule is noted intraoperatively, close monitoring should be performed because of the higher risk of PM exposure.

Suggestions

Du même auteur

Apport de l'imagerie « en face » en tomographie par cohérence optique dans l’évaluation de la sévérité des ptérygions et sa corrélation avec la microscopie confocale in vivo

Archive ouverte | Bunod, Roxane | CCSD

International audience. Purpose: To describe en face anterior segment optical coherence tomography (EF-OCT) characteristics of pterygia and their correlation with in vivo confocal microscopy (IVCM). Patients and met...

Follow-Up of Nonarteritic Anterior Ischemic Optic Neuropathy With Optical Coherence Tomography Angiography

Archive ouverte | Augstburger, Edouard | CCSD

International audience. Purpose: The purpose of this study was to describe capillary changes in patients with nonarteritic anterior ischemic optic neuropathy (NAION) using optical coherence tomography-angiography (O...

Assessment of corneal epithelial thickness mapping in epithelial basement membrane dystrophy

Archive ouverte | Buffault, Juliette | CCSD

International audience. Purpose To investigate the corneal epithelial thickness topography with optical coherence tomography (OCT) and its relationship with vision quality in epithelial basement membrane dystrophy (...

Chargement des enrichissements...