Emergency ward ultrasound: clinical audit on disinfection practices during routine and sterile examinations

Archive ouverte

Andolfo, A. | Maatoug, R. | Peiffer-Smadja, N. | Fayolle, C. | Blanckaert, K.

Edité par CCSD ; BioMed Central -

International audience. Context: In the emergency ward, where the use of ultrasound is common (including for sterile procedures), ward equipment is constantly exposed to high risks of microbiological contamination. There are no clear guidelines for disinfection control practices in emergency departments, and it is not known how emergency ward doctors follow good hygiene practices.Method: A multi-centre audit was conducted in 16 emergency services from Northern France regional hospitals, in form of a questionnaire. It was proposed to all emergency ward physicians. We excluded questionnaires when physicians mentioned that they did not use ultrasound on a daily basis. The questionnaire was designed using existing hygiene and ultrasound disinfection practices guidelines from varying French medical societies. It included three different clinical scenarios: (a) ultrasound on healthy skin, (b) on injured skin, and (c) ultrasound-guided punctures. All questions were closed-ended, with only one answer corresponding to the guidelines. We then calculated compliance rates for each question, each clinical situation, and an overall compliance rate for all the questions.Results: 104 questionnaires were collected, and 19 were excluded. For the 85 analysed questionnaires, the compliance rates were 60.4% 95% CI [56.4-64.7] for ultrasound on healthy skin, 70.9% 95% CI [66.3-76.1] on injured skin and 69.4% 95% CI [65.1-73.6] for ultrasound-guided punctures. The overall compliance rate for the compliance questions was 66.1% 95% CI [62.8-69.1]. Analysis of the questionnaires revealed severe asepsis errors, misuse of gel, ignorance of infection control practices to be applied in the context of ultrasound-guided puncture and exposure of the probe to body fluids.Conclusion: This study details areas for quality improvement in the disinfection of emergency ultrasound scanner use. Consequently, we propose a standardized protocol based upon the recommendations used for the questionnaire drafting, with a visual focus on the low compliance points that have been revealed in this audit. This protocol has been distributed to all the medical emergency services audited and included in the emergency resident's ultrasound learning program.

Suggestions

Du même auteur

Preface Ecohydraulics : linkages between hydraulics, morphodynamics and ecological processes in rivers.

Archive ouverte | Blanckaert, K. | CCSD

International audience. The articles in this issue are a selection of the 15 main presentations made at the EUROMECH Colloquium 523 'Ecohydraulics: linkages between hydraulics, morphodynamics and ecological processe...

Prospective evaluation of the management of urinary tract infections in 134 french nursing homes

Archive ouverte | Lemoine, L. | CCSD

International audience. OBJECTIVE: Prospective assessment of the management of urinary tract infections (UTI) in the nursing homes of the Hauts-de-France region.METHODS: A 50-question form had to be filled in for up...

Accuracy of continuous subcutaneous glucose monitoring with the GlucoDay in type 1 diabetic patients treated by subcutaneous insulin infusion during exercise of low versus high intensity.

Archive ouverte | Fayolle, C. | CCSD

AIM: The GlucoDay allows continuous glucose monitoring by subcutaneous microdialysis in sedentary conditions. To validate it when glycaemia may undergo rapid and dramatic changes, we investigated its accuracy during two exercise s...

Chargement des enrichissements...