Assessment of left ventricle magnetic resonance temperature stability in patients in the presence of arrhythmias

Archive ouverte

Ozenne, Valéry | Bour, Pierre | de Senneville, Baudouin Denis | Toupin, Solenn | Vaussy, Alexis | Lepetit‐coiffé, Matthieu | Jaïs, Pierre | Cochet, Hubert | Quesson, B.

Edité par CCSD ; Wiley -

International audience. List of abbreviations and Declarations are specified at the end of the main text (after Conclusion).BACKGROUND:Magnetic resonance (MR) thermometry allows visualization of lesion formation in real-time during cardiac radiofrequency (RF) ablation. The present study was performed to evaluate the precision of MR thermometry without RF heating in patients exhibiting cardiac arrhythmia in a clinical setting. The evaluation relied on quantification of changes in temperature measurements caused by noise and physiological motion.METHODS:Fourteen patients referred for cardiovascular magnetic resonance imaging underwent an extra sequence to test the temperature mapping stability during free-breathing acquisition. Phase images were acquired using a multi-slice, cardiac-triggered, single-shot echo planar imaging sequence. Temperature maps were calculated and displayed in real-time while the electrocardiogram (ECG) was recorded. The precision of temperature measurement was assessed by measuring the temporal standard deviation and temporal mean of consecutive temperature maps over a period of three minutes. The cardiac cycle was analyzed from ECG recordings to quantify the impact of arrhythmia events on the precision of temperature measurement. Finally, two retrospective strategies were tested to remove acquisition dynamics related either to arrhythmia events or sudden breathing motion.RESULTS:ECG synchronization allowed categorization of inter-beat intervals (RR) into distinct beat morphologies. Five patients were in stable sinus rhythm, while nine patients showed irregular RR intervals due to ectopic beats. An average temporal standard deviation of temperature of 1.6°C was observed in patients under sinus rhythm with a frame rate corresponding to the heart rate of the patient. The temporal standard deviation rose to 2.5°C in patients with arrhythmia. The retrospective rejection strategies increased the temperature precision measurement while maintaining a sufficient frame rate.CONCLUSIONS:Our results indicated that real-time cardiac MR thermometry shows good precision in patients under clinical conditions, even in the presence of arrhythmia. By providing real-time visualization of temperature distribution within the myocardium during RF delivery, MR thermometry could prevent insufficient or excessive heating and thus improve safety and efficacy.

Suggestions

Du même auteur

MRI monitoring of temperature and displacement for transcranial focus ultrasound applications

Archive ouverte | Ozenne, Valéry | CCSD

International audience

A fast MR-thermometry method for quantitative assessment of temperature increase near an implanted wire

Archive ouverte | Quesson, B. | CCSD

International audience. To propose a MR-thermometry method and associated data processing technique to predict the maximal RF-induced temperature increase near an implanted wire for any other MRI sequence.

Impact of Spacing and Orientation on the Scar Threshold With a High-Density Grid Catheter

Archive ouverte | Takigawa, Masateru | CCSD

International audience. BACKGROUND: Multipolar catheters are increasingly used for highdensity mapping. However, the threshold to define scar areas has not been well described for each configuration. We sought to el...

Chargement des enrichissements...