Biomechanical comparison of two locking plate constructs under cyclic loading in four-point bending in a fracture gap model: two screws versus three screws per fragment

Archive ouverte

Palierne, Sophie | Froidefond, Baptiste | Swider, Pascal | Autefage, André

Edité par CCSD ; Schattauer -

International audience. OBJECTIVES: The number of locking screws required per fragment during bridging osteosynthesis has not been fully determined in the dog. The purpose of this study was to assess the survival of two constructs, with either two or three screws per fragment, under cyclic bending. METHODS: A 10-hole, 3.5-mm stainless steel locking compression plate was fixed 1 mm away from a bone surrogate in which the fracture gap was 47 mm. Two groups of 10 constructs, prepared with either two or three bicortical locking screws placed at the extremities of each fragment, were tested in a load-controlled 4-point bending test (range 0.7 to + 7 Nm) until failure. RESULTS: The 3-screw constructs were stiffer than the 2-screw constructs (19.73 ± 0.68 N/mm vs. 15.52 ± 0.51 N/mm respectively) and the interfragmentary relative displacements were higher for the 2-screw constructs (11.17 ± 0.88%) than for the 3-screw constructs (8.00 ± 0.45%). The difference between the number of cycles to failure for the 3-screw constructs (162,448 ± 30,073 cycles) and the 2-screw constructs (143,786 ± 10,103 cycles) was not significant. Failure in all constructs was due to plate fracture at the level of the compression holes. CLINICAL SIGNIFICANCE: Omission of the third innermost locking screw during bridging osteosynthesis subjected to bending forces led to a 20% reduction in construct stiffness and increased relative displacement (+39.6%) but did not change fatigue life.

Suggestions

Du même auteur

Biomechanical Comparison of Use of Two Screws versus Three Screws Per Fragment with Locking Plate Constructs under Cyclic Loading in Compression in a Fracture Gap Model

Archive ouverte | Palierne, Sophie | CCSD

International audience. Abstract Objectives The aim of this study was to measure and compare the stiffness and cyclic fatigue of two plate-bone model constructs, with either two or three locking screws per fragment,...

Comparison of the effect of locking vs standard screws on the mechanical properties of bone-plate constructs in a comminuted diaphyseal fracture model

Archive ouverte | Verset, Michaël | CCSD

International audience. The purpose of this study was to compare the mechanical properties of bone-plate constructs with LCP plates used either with standard screws or with locking screws on an experimental model of...

Effective mechanical properties of diaphyseal cortical bone in the canine femur

Archive ouverte | Autefage, André | CCSD

International audience. The effective elastic modulus, yield strength, yield strain, ultimate strength, ultimate strain, strain energy density at yield and strain energy density at ultimate failure of femoral diaphy...

Chargement des enrichissements...